Icom IC F121S User Manual

Page 13

Advertising
background image

5 - 2

Personal
computer

to the MIC
connector

to an RS-232C port

DB9 female plug

RS-232C cable
(straight)

*OPC-1122
(JIG CABLE)

AC millivoltmeter

Audio generator

FM deviation meter

(DC measurable)

Attenuator

40 dB or 50 dB

to the antenna connector

to DC cable

Standard signal generator

–127 to –17 dBm

(0.1

µV to 32 mV)

CAUTION:
DO NOT
transmit while
the SSG is connected to
the antenna connector.

RF power meter

50

Ω / 1–100 W

DC power supply

13.2 V / 15 A

Frequency

counter

• Connections

REQUIRED TEST EQUIPMENT

EQUIPMENT

DC power supply

RF power meter
(terminated type)

Frequency counter

FM deviation meter

Digital maltimeter

GRADE AND RANGE

Output voltage

: 13.2 V DC

Current capacity

: 15 A or more

Measuring range

: 1–100 W

Frequency range

: 100–300 MHz

Impedance

: 50

SWR

: Less than 1.2 : 1

Frequency range

: 0.1–300 MHz

Frequency accuracy : ±1 ppm or better
Sensitivity

: 100 mV or better

Frequency range

: DC–300 MHz

Measuring range

: 0 to ±10 kHz

Input impedance

: 50 k

Ω/V DC or better

EQUIPMENT

Audio generator

Standard signal
generator (SSG)

Oscilloscope

AC millivoltmeter

External speaker

Attenuator

GRADE AND RANGE

Frequency range

: 300–3000 Hz

Measuring range

: 1–500 mV

Frequency range

: 0.1–300 MHz

Output level

: 0.1 µV–32 mV

(–127 to –17 dBm)

Frequency range

: DC–20 MHz

Measuring range

: 0.01–20 V

Measuring range

: 10 mV–10 V

Input impedance

: 4

Capacity

: 7 W or more

Power attenuation

: 40 or 50 dB

Capacity

: 100 W or more

Advertising