Ingersoll-Rand NO SE ENCUENTRA 150BMG User Manual

Page 6

Advertising
background image

6

03524832_ed12

150BMG Series Air and Gas Starters Typical Installation

T

o

rq

ue (lb

-f

t)

P

o

w

e

r (HP)

F

lo

w

(SCF

M)

Series 150BM and 150BMG Performance Curves

0

20

40

60

80

100

120

25

20

15

10

300

600

900

1200

5

0

0

500

1000

1500

Speed (RPM)

2000

2500

3000

Starter

3BM, 5BM

0-30’

# 12 (3/4 “)

SRV 100
SRV 100
SRV 100
SRV 125

SRV 150

# 12 (3/4 “)

# 16 (1 “)

# 20 (1 1/4“)

# 24 (1 1/2“)

0-30’
0-10’

10-30’

0-50’

SS175

150BM/LF, SS350

SS810, 815, 825, 850
ST750, 799

Hose Length

Hose Size

SRV Size

The performance of the Starter is dependent on the pressure at the inlet of the starter.
This pressure is effected by the pressure drop between the Air Receiver Tank and the Starter.
The most significant pressure drops will occur in fittings (Valves, Tees, Elbows, etc.)
The next significant source of pressure drop is the hose. The following table provides
recommended hose and Starter Relay Valves (SRV) sizes for typical one starter installations.
Systems with many fittings or long hose should be analyzed and sized individually.

For Gas Operation the exhaust outlet must be piped
away to a safe location.

For Natural Gas Operation, Piped Exhaust must be
used and Drive Housing vent plug replaced with
suitable hose which connects into piped exhaust
system.

For Air Applications a Muffler or Splash Guard
Deflector must be used.

Ingersoll Rand Part Number

Starter control Valve
SMB-G6618

Air Pressure Gage
150BMP-1064L

Check Valve
150BMP-1056

Drain Valve
150BMP-1067
1/2 NPT

# 4 Hose (1/4”)

# 4 Hose (1/4”)

# 4 Hose (1/4”)

JIC 37˚ Adapter
1 1/2 NPT

Air

Receiver

Tank

1 1/2” NPT

HDL3 Luricator

See Recommended
Hose Size

JIC 37˚ Adapter
1/4 NPT

Air Supply

Note:
Use Seleant on all pipe connections.
SMB-441

(Dwg. TPC585)

(Dwg. TPC611)