Trouble shooting, Dimensional data – Ingersoll-Rand PD07X-X-X User Manual

Page 8

Advertising
background image

Page 8 of 8

PD07X-X-X (en)

PN 97999-1226

TROUBLE SHOOTING

Product discharged from air exhaust.

Check for diaphragm rupture.
Check tightness of (14) bolt.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check “O” rings between intake manifold and fl uid caps.
Check tightness of (14) bolt.

Pump blows air out main exhaust when stalled on either
stroke.

Check “U” cups on (111) spool in major valve.
Check (141) valve plate and (140) insert for wear.
Check (169) “U” cup on (167) pilot piston.

y

y

y

y

y

y

y

y

Low output volume.

Check air supply.
Check for plugged outlet hose.
For the pump to prime itself, it must be mounted in the
vertical position so that the balls will check by gravity.
Check for pump cavitation - suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper fl ow if high viscosity fl uids are being pumped.
Suction hose must be non-collapsible type, capable of
pulling a high vacuum.
Check all joints on the intake manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.

y

y

y

y

y

y

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 5

DIMENSIONS

A - 9-9/32” (235.3 mm)

E - 6-23/32” (170.6 mm)

J - 5-1/2" (139.7 mm)

N - 6-5/16" (159.8 mm)

B - 11-1/16” (280.4 mm)

F - 6” (152.4 mm)

K - 5/16” (8.0 mm)

P - see below

C - 6-1/8” (155.6 mm)

G - 11-7/8” (301.2 mm)

L - 3-29/32” (99.2 mm)

D - 2” (50.8 mm)

H - 4-29/32” (124.2 mm)

M - 3/8” (9.5 mm)

Air Inlet 1/4 - 18 P.T.F. SAE Short

M

(Outlet)

P

A

C

K

H

J

D

B

G

F

E

L

N

(Inlet)

P

Pump Model

“P” Material Inlet / Outlet

PD07R-AAS-XXX

3/4 - 14 N.P.T.F. - 2

PD07R-BAS-XXX

Rp 3/4 (3/4 - 14 BSP, parallel)

Advertising