1 rmon alarm : create new alarm, Figure 79 rmon alarm : create new alarm, Table 60 rmon alarm : create new alarm – IronPort Systems ES-1528 User Manual

Page 127

Advertising
background image

Chapter 19 RMON-Lite

ES-1528 User’s Guide

127

19.5.1 RMON Alarm : Create New Alarm

Use the RMON Alarm : Create New Alarm screen to configure RMON alarms. Click
Create new Alarm or click on an existing alarm index entry in the RMON Alarm :
Overview
screen to view the screen as shown.

Figure 79 RMON Alarm : Create New Alarm

The following table describes the labels in this screen.

RisingThreshold This field displays the rising threshold value set up for this alarm.
FallingThreshol

d

This field displays the falling threshold value set up for this alarm.

Rising Event

Index

This field indicates the index number of the event entry which corresponds to the

time when the alarm threshold was crossed.

Falling Event

Index

This field indicates the index number of the event entry which corresponds to the

time when the alarm threshold was crossed.

Owner

This field displays the name of the creator of this entry.

Delete

Click this to remove the selected alarm entry.

Table 59 RMON Alarm: Overview (continued)

LABEL

DESCRIPTION

Table 60 RMON Alarm : Create New Alarm

LABEL

DESCRIPTION

RMON MIB

Table:

Use this drop down list box to select the MIB table you want to view. Click Apply to

refresh the screen to the selected MIB table view.

Index

This field displays the index number of this alarm entry.

Interface

Select the port which is monitored for this alarm.

Counter

Select the data which is used to test if this alarm is triggered, the choices are Drop

Events, Octets, Packets and so on.