Ives Heavy Duty Offset Top Pivot 7237F User Manual

Page 2

Advertising
background image

26365 Rev. 3

Right hand installation shown;

left hand opposite

It is very important for installer to verify that center line of intermediate pivot point
lines up with center line of top and bottom pivot points before final installation.
Both door and frame pivot leafs located from face of door. Intermediate pivot
should be evenly spaced between top and bottom pivots. Heel edge of door
must be beveled 1/8” in 2”.

NOTE

!

Frame Leaf

Door Leaf

Face of door

1/2”

13 mm

3/4”

19 mm

5/16”

8 mm

5/16”
8 mm

3/8”

10 mm

Reference line

7/16”
11 mm

C

L

3/4”
19 mm

1-1/4”
32 mm

Face
of door

C

L

26365-00

Advertising