Plus, Mdrive17, Microstepping – Intelligent Motion Systems MDM17Plus User Manual

Page 2: Standard spec i fi ca tions setup parameters, Motor spec i fi ca tions, Encoder pin assignments, Internal encoder external encoder

Advertising
background image

2 MDrive17Plus Microstepping

REV060208

Holding Torque

Detent Torque

Rotor Inertia

Weight (Motor+Driver)

SINGLE LENGTH

32 oz-in / 22.6 N-cm

1.66 oz-in / 1.17 N-cm

0.00053 oz-in-sec

2

/ 0.038 kg-cm

2

10.4 oz / 294.8 g

DOUBLE LENGTH

60 oz-in / 42.4 N-cm

2.08 oz-in / 1.47 N-cm

0.00080 oz-in-sec

2

/ 0.057 kg-cm

2

12.0 oz / 340.2 g

TRIPLE LENGTH

74.9 oz-in / 52.9 N-cm

3.47 oz-in / 2.45 N-cm

0.00116 oz-in-sec

2

/ 0.082 kg-cm

2

15.2 oz / 430.9 g

MDrive17

Plus

MICROSTEPPING

INPUT VOLTAGE (+V)

Range

+12 to +48 VDC

Power supply current requirements = 2A (maximum) per MDrive17Plus.
Actual power supply current will depend on voltage and load.

ISOLATED INPUT

Universal

Voltage Range: +5 to +24 VDC Sourcing or Sinking
Step Clock, Direction and Enable

Differential

Voltage Range: +5 VDC
Clockwise and Counterclockwise

MOTION

Digital Filter Range

50 nS to 12.9 µS (10 MHz to 38.8 kHz)

Clock Types

Step/Direction, Quadrature, Step Up/Step Down, Clockwise/Counterclockwise

Step Frequency

2 MHz Default / 5 MHz Max

Resolution

Number of Settings

20

Steps Per Revolution

200, 400, 800, 1000, 1600, 2000, 3200, 5000,
6400, 10000, 12800, 20000, 25000, 25600,
40000, 50000, 51200, 36000 (0.01 deg/µstep),
21600 (1 arc minute/µstep), 25400 (0.001mm/µstep)

THERMAL

Operating Temperature

Heat Sink

–40° to +85°C (non-condensing)

Motor

–40° to +100°C (non-condensing)

STANDARD SPEC I FI CA TIONS

SETUP PARAMETERS

Function

Range

Units

Default

MHC

Motor Hold Current

0 to 100

percent

5

MRC

Motor Run Current

1 to 100

percent

25

MSEL

Microstep Resolution

1, 2, 4, 5, 8, 10, 16, 25, 32, 50, 64, 100,

108, 125, 127, 128, 180, 200, 250, 256

µsteps per full step

256

DIR

Motor Direction Override

0/1

CW

HCDT

Hold Current Delay Time

0 or 2–65535

mSec

500

CLK TYPE

Clock Type

Step/Dir, Quadrature, Up/Down, CW/CCW

Step/Dir

CLK IOF

Clock and Direction Filter

50 nS to 12.9 µS

(10 MHz to 38.8 kHz)

nS ( MHz)

200 nS (2.5 MHz)

USER ID

User ID

Customizable

1–3 characters

IMS

EN ACT

Enable Active

High/Low

High

Optional encoder cables are available.

MOTOR SPEC I FI CA TIONS

All parameters are set using the supplied IMS SPI Motor Interface GUI and may be changed on-the-fl y.
An optional Communication Converter is recommended with fi rst orders.

ENCODER PIN ASSIGNMENTS

DIFFERENTIAL ENCODER

with locking connector feature

SINGLE-END ENCODER

Pluggable Interface

Function

Function

Pin 1

No Connect

Ground

Pin 2

+5 VDC Input

Index

Pin 3

Ground

Channel A

Pin 4

No Connect

+5 VDC Input

Pin 5

Channel A –

Channel B

Pin 6

Channel A +

Pin 7

Channel B –

Pin 8

Channel B +

Pin 9

Index –

Pin 10

Index +

Internal Encoder

External Encoder

An internal differential encoder option is available on
MDrive17Plus Microstepping regular and IP65 sealed
versions.

See Wire/Pin Assignments on the following page for
connection details.

Advertising