Burner and nozzles characteristics – Indesit KG6408 XV/G User Manual

Page 5

Advertising
background image

5

Rotate to the left to increase the flame and rotate to
the right o lower the flame.

N.B.: in the case of liquide gas, the regulation screw must
be screwed in the bottom.
Check that the flame does not turn off when you turn the
tap quickly from hugh to low

A

B

S

T

C

B

A

B

Fig. A

Fig. B

Attention:
On completion of the above operation, please replace the
current technical data label with a new one containing
details of the gas which the appliance has now been
converted to. The new technical data label is contained in
the nozzles Kit supplied with the cooker.

Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.
Table 1

Regulating air "a" (mm)

Burner

Butane

Propane

Natural Gas

G 20

Fast large
(Front right)

Fast
(Rear left)

Medium
(Rear right)

Medium
(Front left)

11

13

13

13

0

0

0

0

a

Table 2

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal power

kW

(p.c.s.*)

By-pass

1/100

(mm)

Nozzle

1/100

(mm)

Flow*

g/h

Nozzle

1/100

(mm)

Flow*

l/h

Max

Min.

***

**

Front-Right

90

3.30

0.70

42

90

240

236

135

314

Rear-Left

78

2.70

0.70

42

83

196

193

122

257

Front-Left

50

1.70

0.40

29

65

124

121

97

162

Rear-Right

50

1.70

0.40

29

65

124

121

97

162

Supply
pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

37**
25**
45**

28-30***

20***
35***

20

17

25

*

At 15°C and 1013 mbar-dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

Natural

P.C.S. = 37,78 MJ/m

3

Burner and nozzles characteristics