OPERATING PROCEDURES

x The 9:1 ratio is an expression of the relationship between the effec-

tive air motor area and the effective lower pump area. When 120 PSI
(10 bar) of air pressure is supplied to the air motor, the lower pump
end will develop a maximum of 1,350 PSI (93 bar) of fluid pressure
(at no flow) as the fluid control is opened, the flow rate will increase
as the air motor cycle rate increases to keep up with the demand.

x Flush system. This pump has been tested in kerosene and a small

amount remains in the pump end. Kerosene must be flushed from
the pump before using. To flush system:

x Gun or dispensing device should be removed.
x Immerse fluid or suction hose in a 5 gallon pail of compatible solvent.
x Place material outlet hose into pail.
x Regulate air pressure to a few pounds.
x Connect air supply to air motor inlet.
x Allow pump to cycle slowly and circulate solvent for awhile.
x Disconnect air supply.
x To Prime System:
x Install gun or dispensing device to material outlet hose.
x A shut-off valve located on the cart should be in the “off” position

(handle perpendicular to valve body). Connect air line to connector
(See figure 1).

x With air line connected to connector, the lift assembly and pump will

rise.

x Once lift assembly and pump are in the “up” position, place and cen-

ter opened 5 gallon pail of material under follower plate (5).

x Remove vent plug from follower plate (5). Trapped air must be re-

moved from beneath the follower plate.

x Disconnect the main air line to the connector and allow pump and lift

assembly to lower into 5 gallon pail of material. Once the follower
plate (5) begins to force material out of the vent plug, reseat bleed
plug.

x Once the follower has been properly seated, prior to pumping, be

sure the thumb screws on the cart are tightened to secure 5 gallon
pail. Pail must be locked in place with thumb screws before the fol-
lower plate can be removed from 5 gallon pail.

x Djustment knob on air regulator (1) should be turned counter-clock-

wise until it turns free to prevent overpressurizing the pump.

x Connect air line to air regulator (1). Adjust knob on the air regulator

(1) until pump begins to cycle.

x Trigger (13) gun to prime pump with material.
x If pump does not stop or material does not flow from dispensing

valve, refer to Troubleshooting Section of this manual.

DAILY MAINTENANCE

x Lack of or an excessive amount of lubeication will affect the perfor-

mance and life of this pump. Use only recommended lubricants.

x DAILY - Fill air line lubricator reservoir with SAE NO. 90W non-deter-

gent gear oil.

x If pump is to be inoperative for more than a few hours at a time, dis-

connect air supply and relieve all pressure from the system.

x This manual covers the basic pump unit. The 4-1/4” air motor is com-

pletely separate from the lower pump end. This helps to keep the air
motor from being contaminated by material being pumped.

x Periodically flush entire pump system with a solvent that is compat-

ible with the material being pumped.

x Keep solvent cup filled with this compatible solvent. This will keep

material from drying on the piston rod, which would drag thru the
packings, ruin them and eventually scour the piston rod.

x Refer to Disassembly Procedures of air motor for correct break

down.

x Disassembly should be done on a clean work bench with clean

cloths to keep parts clean.

x If replacement parts are necessary, consult drawing containing

parts for identification.

x Before assembling, lubricate parts where required. When assem-

bling “O” rings or parts adjacent to “O” rings, care must be exercised
to prevent damage to “O” rings and “O” ring groove surfaces.

MAINTENANCE

x When the following instructions are observed, heavy paste materi-

als can be pumped directly from their original 5 gallon pail without air
inclusion, or excessive waste. The follower plate creates an air tight
seal as well as clean-wiping action in its progressive downward
movement into the pail.

x Lubricate lower follower wiper plate seal with any type grease (sili-

cone, vaseline, gear, etc.). This ensures a smooth fit into the pail as
well as prevents curing type compounds from bonding to the seal.

x Check vent plug to be sure it easily threads in and out. It is recom-

mended to lubricate the threads of the plug to help prevent possible
set up of compound at this point. See 65184X-X Operator’s Manual.

TO CHANGE THE PAIL

x Turn knob on pump air regulator (1) counter-clockwise to turn air

“off” to pump.

x Turn shut-off control valve to “ON” position (Handle parallel with

body) to apply pressure under follower plate.

x Disconect main air line from pump air regulator (1) and connect to air

line connector on cart.

x Allow pump and lift assembly to clear the top of the 5 gallon pail of

material.

x Turn shut-off controll valve tp “OFF” postition. (Handle perpendicu-

lar to valve body).

x Unscrew thumb screws. Remove empty pail of material and replace

with a new pail of material.

x Secure new pail of material with thumb screws. Remove vent plug

from follower plate (5).

x Disconnect main air line from connector and allow lift assembly to

lower into new 5 gallon pail of material. Once the (5) follower plate
begins to force material out of the vent plug, reseat bleed plug.

TROUBLESHOOTING

x Malfunctions beyond the scope of this manual should be brought to

the attention of your ARO Representative.

x PROBLEM
-

Cause, Solution

x No material coming from extrusion nozzle
-

Obstructed Material, Remove tip and clean

-

Obstructed Hose, Remove control handle and cycle pump until hose
is clear

-

Obstructed Control Handle, Disassemble control handle and clean