Mounting the tank connecting faucet to tank – InSinkErator H770 User Manual

Page 10

Advertising
background image

A

Select a spot under the sink to mount
tank vertically within reach of both
plumbing and electrical connections.
The tank should be within 16" or less
of faucet water lines and within 30"
or less of a standard grounded outlet.

While holding tank in place on
the spot selected for installation,
use a pencil to mark locations for
2 hanging screws.

Property Damage: Tank must be located within 16" of
faucet and within 30" or less of a standard grounded

outlet. DO NOT extend plumbing or electrical lines.

3

Without depressing the gray button,
place the snap-connect fitting at
the end of the blue 1/4" tube onto
the left fitting on the tank, pushing
until it clicks into place. (1)

Slip the flexible white 7/16" tube
over barbed middle fitting and slide
down approximately 1/2". (2)

Slip the clear 5/16" tube over the far
right smooth fitting and slide down
approximately 1/2". (3)

Visually check for pinched or
crimped tubes.

4

A

Property Damage: Pinched or blocked water lines

may cause damage to the dispenser tank.

Tank must be

mounted level

to ensure

proper operation.

Hose clamps are not needed for any

of the connections.

Mount tank vertically in an area that

allows clearance on the underside of the

tank for drainage, if necessary.

DO NOT over tighten screws.

Pre-drill 1/8" pilot holes at marks.

Turn screws into pre-drilled holes,
leaving 1/4" exposed.

Hang the tank on the screws.

Tighten the screws with only 1/2 turn
clockwise.

B

Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.

Leave 1/4" for

hanging tank.

Property Damage: Check to make sure

tubes are connected properly and are

pushed down as far as possible.

(1)

(2)

(3)

10

MOUNTING THE TANK

CONNECTING FAUCET TO TANK

Advertising