Burner and nozzle characteristics – Indesit K 647 GS/G User Manual

Page 7

Advertising
background image

7

V

I

Fig. E

Fig. F

Important: when mounting the grill burner check that there
is a space of at least 4 mm between the security
thermocouple (if installed) and the burner.

4 mm

Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.

Burner and nozzle characteristics

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal Power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nominal

Reduced

(mm)

(mm)

***

**

(mm)

Fast
(Large)(R)

100

3.00

0.7

41

86

218

214

116

286

Semi Fast
(Medium)(S)

75

1.90

0.4

30

70

138

136

106

181

Auxiliary

(Small)(A)

55

1.00

0.4

30

50

73

71

79

95

Triple Crown

(TC)

130

3.25

1.5

63

91

236

232

133

309

Oven

-

3.02

1.0

49

85

219

216

132

288

Grill

-

2.50

-

-

80

182

179

122

227

Supply

Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20

17

25

*

At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

Natural

P.C.S. = 37,78 MJ/m

3

S

S

R

A

TC

A

S

R

K 642 G/G

K 647 GS/G

K 642 GS/G

Advertising