CABLE SIZE:
When a long electric extension cord is used to connect an appliance or

tool to the generator, a certain amount of voltage drop or loss occurs in

the extension cord which reduces the effective voltage available for the

appliance or tool. The chart below has been prepared to illustrate the

approximate voltage loss when an extension cord of 300 feet (approx.

100 meters) is used to connect an appliance or tool to the generator.

Equipment damage can result from low voltage. Therefore, to prevent

excessive voltage drop between the generator and the equipment,

the cable should be of adequate gauge for the length used. The cable

selection chart gives the maximum cable lengths for various gauges of

wire which can adequately carry the loads shown.

CURRENT LOAD IN WATTS MAXIMUM CABLE LENGTH (FEET)
IN AMPS 120 VOLTS 240 VOLTS #8 WIRE #10 WIRE #12 WIRE

#14 WIRE

#16 WIRE

2.5 300 600 1000 600

375

250

5 600 1200 500 300

200

125

7.5 900 1800 350 200

125

100

10 1200 2400 250 150

100

50

15 1800 3600 150 100

65

20 2400 4800 175 125 75

50

25 3000 6000 150 100 60
30 3600 7200 125 65
40 4800 9600 90