8.1B No Heat Or Not Enough Heat

• Symptoms: Circulation pump (heating pump) not turning, panel heat indicator not lit,
panel is fl ashing FL2.

Standard Troubleshooting Approach

Pull wire off flow
switch. Does the
FL2 error message
go away?

Replace wire.

Turn off power to hot
tub. Test flow switch
with ohmmeter for
continuity across
switch terminals (fig.
D-E). Does meter
read continuity
(0)?

Remove flow switch
and inspect for
debris interference.
Remove debris if
present. Test switch
for continuity (0)
when closed and for
infinite when open
(fig. E). Does switch
operate correctly?

Make sure wire is
not shorted when
installed on switch.

Install switch making
sure flow arrow
points in direction of
flow and switch
doesn’t bottom in
fitting (fig. F). Retest
system.

Is wire shorted?

No

No

Yes

Yes

Yes

Yes

No

Replace flow switch.

No

Replace circuit
board.

Fig. D

Infinite

Continuity 0

Fig. E

Infinite

Continuity 0

FLOW

Orientation

Orientation

FLOW

Fig. F

Pipe End

View

OK

Arrows not

aligned

Arrows

aligned

Open

Closed

Pump

off

Pump

on