Controls and Features

Remote Control:

Time button (A, Fig. 2) controls the three
different settings.

2H will light up on the back of the unit with one
press of the time button.

The air filtration

system will operate for 2 hours then shut off.

4H will light up on the back of the unit by
pressing the time button twice. The air filtration
system will operate for 4 hours then shut off.

8H will light up on the back of the unit by
pressing the time button three times.

The air

filtration system will operate for 8 hours then
shut off.

Speed button (B, Fig. 2) controls the three
different settings, Low, Medium and High. There
is also a manual button (C, Fig. 2) on the
backside of this unit which controls the speed.

On/Off button (D, Fig. 2) turns the unit on and
off. There is also a manual on/off button (E, Fig.
2) on the backside of the unit.

Pressing this

button will turn the machine on Low.

Overload reset switch (F, Fig. 2) will pop in the
case of overload. Wait 3-5 minutes and press
the reset switch.

Changing the Filters



WARNING

To reduce the risk of injury disconnect the

air filtration unit from the power source

(unplug) before servicing or changing

filters. Failure to comply may cause

serious injury!

Outer Filter: remove from the side of the

cabinet

(A, Fig. 3).

This filter should be

replaced

depending

on

the

usage

and

environment

of

your

shop.

JET sells a

replacement metal framed filter that can be
blown out or washed, (stock # 708724 shown in
figure 3).