8. Specifications


Specifications

CV-A11

Scanning System

Progressive 525 lines 30 frames/sec

Frame rate (Full frame)

29.96 Hz

Line frequency

15.734 kHz

CCD sensor

Monochrome 1/3” IT CCD. Sony ICX424AL, (ICX084AL-6, old)

Sensing area

4.9 (h) x 3.7 (v) mm

Effective pixels

659 (h) x 494 (v)

Pixels in video output

648 (h) x 492 (v)

Cell size

7.4 (h) x 7.4 (v) µm

Resolution horizontal

480 TV lines

Sensitivity on sensor

0.05 Lux, Max gain, 50% video

S/N ratio

> 56dB

Video output

Composite VS signal, 1.0 Vpp, 75 Ω, DC Coupled

Gamma

0.45 or 1.0

Gain
Gain range

Manual – Automatic

0 to + 15 dB

Accumulation

Frame (Progressive scan)

Synchronization

Int. x-tal, Ext HD/VD or random trigger

HD sync Input/output

4 Vpp, 75Ω

Trigger input

4 Vpp, 75Ω

WEN output (write enable)

4 Vpp, 75Ω

EEN output (exposure enable)

4 Vpp, 75Ω

Pixel clock output

4 Vpp,75Ω

Shutter

1/30, 1/50, 1/60, 1/125,1/250,1/500, 1/1000,

1/2000,1/4000, 1/10 000, 1/20 000, 1/40 000,

1/80 000,1/100 000 sec.

Pulse width control

1.5 H to 1000H

Start/stop

1/30 to 1/10 000 second

Long time exposure

1 frame to ∞

Programmable exposure

0.5H to 1023.5H

Frame delay readout

Time from PWC trigger input to ext. VD input

Functions controlled by

RS-232C

Scanning format, Trigger mode, Shutter speed,

Trigger/WEN polarity, Accumulation, Shutter mode,

Programmable exposure, AGC level, White clip,

Setup, Manual gain, AGC/manual gain, Internal/

Potentiometer gain set, Gamma, Pixel clock,

Commands and internal adjustments.

Functions controlled by
Internal DIP switches

VD input/output, HD input/output

HD, VD and 75Ω termination on/off

Operating temperature

-5 to + 45

Humidity

20 – 80% non-condensing

Storage temp./humidity

-25 to 60 /20% - 80%

Power

12V DC ± 10%, 1.8W Max.

Lens mount

C-mount

Dimensions

29 x 44 x 66mm (HxWxD)

Weight

150g

9. Spectral Sensitivity

400

500

600

700

800

900

Wave Length (nm)

1.0

0.8

0.6

0.4

0.2

0.0

Relative Response

1000

Fig. 27. Spectral sensitivity.

- 21 -

Advertising