Stove

Unprotected Surface

Protected Surface Installation

Clearances

Installation

PER NFPA211 OR CAN/CSA -B365-M93

Side

Rear

Corner*

Side

Rear

Corner*

Stove -no heatshield

19" A

25" B

18" C

11” D

7" E

8" F

single wall pipe

485mm

635mm

460mm

280mm

180mm

205mm

Stove -with rear heatshield

18" G

18" H

13" I

11” J

7” K

8" L

single wall pipe

460mm

460mm

330mm

280mm

180mm

205mm

Stove -no heatshields

16”

19”

13”

8”

7”

6”

double wall pipe

405mm

485mm

330mm

205mm

180mm

150mm

Stove -with rear heatshield

15" M

7" N

11" O

8" P

7" Q

6" R

with connector shield

380mm

180mm

280mm

205mm

180mm

150mm

Stove -rear heatshield

15" S

7" T

11" U

8" V

7" W

6" X

with double wall pipe

380mm

180mm

280mm

205mm

180mm

150mm

Connector

Unprotected Surface

Protected Surface

Clearances (Pipe)

Vertical Installation

Vertical Inatallation

p

er NFPA211 OR CAN/CSA-B365-M93

Single wall pipe

25"

12"

635mm

300mm

Single wall pipe

18”

7”

with rear heatshield

460mm

180mm

Single wall pipe

7"

7"

with connector shields

180mm

180mm

Double wall pipe

7"

7"

180mm

180mm

Connector

Unprotected Surface

Protected Surface

Clearances (Pipe)

Horizontal Installation

Horizontal Installation

per NFPA211 OR CAN/CSA-B365-M93

Single wall connector

18" 460mm

7" 180mm

Double wall Pipe

6" 150mm

6" 150mm

Mantel and Trim

Stove to 1" thick or less, side trim

13" 300mm

Clearances

Stove to 1" thick or less, top trim

23" 585mm

Stove to mantel- maximum mantel depth 12"

25" 635mm

Jøtul F 400 Woodstove Clearances