This section shows the communication examples of RS-232C.

Operating command

Type

Command

Description

Connection

check

PC→This unit: 21 89 01 00 00 0A

This unit→PC: 06 89 01 00 00 0A

Connection check.

Power (On)

PC→This unit: 21 89 01 50 57 31 0A

This unit→PC: 06 89 01 50 57 0A

When power is turned on from

standby mode.

Power (Off)

PC→This unit: 21 89 01 50 57 30 0A

This unit→PC: 06 89 01 50 57 0A

When power is turned off

(standby mode) from power-on

mode.

Input

(COMP.)

PC→This unit: 21 89 01 49 50 32 0A

This unit→PC: 06 89 01 49 50 0A

When video input is set to

component.

Remote

Control

(MENU)

PC→This unit: 21 89 01 52 43 37 33 32 45 0A

This unit→PC: 06 89 01 52 43 0A

When the same operation as

pressing the [MENU] button

on the remote control is made

Reference command

Type

Command

Description

Power (On)

PC→This unit: 3F 89 01 50 57 0A

This unit→PC: 06 89 01 50 57 0A

This unit→PC: 40 89 01 50 57 31 0A

When information of power-

on mode is acquired.

Input

(HDMI 1)

PC→This unit: 3F 89 01 49 50 0A

This unit→PC: 06 89 01 49 50 0A

This unit→PC: 40 89 01 49 50 36 0A

When information of HDMI 1

input is acquired.