Tsc-66 traditional series, Left to right operation shown – Jackson Traditional Series TSC-66 User Manual

Page 5

Advertising
background image

TSC-66 Traditional
Series

Left to Right Operation Shown

Legend to Drawing

A

– Machine water inlet 1/2” I.P.S., 180°F minimum, 61-

1/4” above finished floor

B

– Electrical connection , approximately 61-1/4” above

finished floor. See table for amperage requirements

C

– Drain connection-1 1/2” I.P.S.

D

– Prewash water inlet 1/2” I.P.S. 110°F - 140°F

*E

–Condensate return connection, 3/4” FPT (return to

boiler feeder or open drain)

*F

– Incoming low pressure steam connection, 3/4” FPT

(gate valve supplied)

*

Steam tank heat option only

Note:

All vertical dimensions are +/- 1/2” from floor due

to adjustable bullet feet

1-PH

3-PH

1-PH

3-PH

*3-PH

208 Volts 60 Cycles

88.3

51.8

18.3

10.1

29.0

230 Volts 60 Cycles

81.5

47.8

18.3

10.1

25.0

460 Volts 60 Cycles

N/A

23.9

N/A

5.1

13.0

TSC-66 Series
Electrical Data

Approximate Total Load Amps

Electric Tank Heat

Steam Tank Heat

Optional 7 KW

Models:

Models:

Electric

TSC-66

TSC-66S

Booster Heater

Recommended Table Fabrication

82”

66” TABLE TO TABLE

22”

5”

13”

61-1/4”

34”

11-1/4”

10”

29”

5”

4-1/2”

6-1/2”

53”

66”

8”

66”

TABLE TO TABLE

8”

12-1/2”

4”

74”

82”

4”

Floor sink or drain with
3” minimum drain line.

26”

8”

10-1/2”

21”

OPENING

4” wide x 16” long cutout in vent
cowl/splash shield. Shipped with
cover plates.

34”

14”

Drive

Motor
Cover

10” high backsplash

Scrap trough location MUST be a
minimum of 14” from the tub,
regardless of which side the trough
is mounted on.

Scrap Trough Location

Optional 12 KW

Electric

Booster Heater

*3-PH

33.0

29.0

14.5

30-1/2”

24”

18”

The maximum recommended distance between any electric
booster heater and the dishmachine is 20 ft.

B

C

E

F

A

D

25”

21”

4”

5-3/4”

W

ALL

Add 3” to machine width to account for con-
duit and/or piping on the back of the machine
when determining doorways and entrances
for the machine to fit through.

All specifications subject to change without notice.

20-1/2”

1”

*

Option electric boosters come in 3 phase only.

Note:

Optional booster heater requires separate electrical connection. 24

KW and 36 KW booster heaters are designed to supply the dishmachine
with rinse water at the appropriate temperature. Models do NOT come
with booster heaters as standard equipment.

Machine height with doors open is 72”.

TSC-66 Drawings Rev B.qxd 11/5/04 7:54 AM Page 1

Advertising