Installation

Installation

L

L

ocate the amplifier as close as possible to its final installation point.

Allow access to the rear panel for making connections.

The Model 12 Mono Power Amplifier is convection cooled,

eliminating the need for fan or forced-air cooling. When operating,

the chassis should have at least two (2) inches of air space around

the heatsink areas. Multiple chassis can be stacked vertically,

facilitating an upward flow of warm air currents throughout the

vertical heatsink areas. This upward flow must not be blocked or

recirculated around the chassis if proper cooling is to be

maintained.

Rear Panel Power Connections

Rear Panel Power Connections

Important:

Important:

Please strictly follow the steps in order as outlined below

before operating your Model 12 Mono Power Amplifier.

11

Verify that the VOLTS AC input identified on the rear panel near

the AC input socket is the same as the AC mains voltage in your

area. If the voltage does not match, do not connect the

amplifier to AC power and contact your dealer immediately.

22

Install the DC Power Supply Cable between the power supply

and the amplifier section. There is a slot cut in the edge of the

connector on each end of the cable, and this slot should be

aligned to face up. Use the knurled ring on the connector to

secure the cable to both the power supply and the amplifier.

33

Verify that the AC MAINS CIRCUIT BREAKER and the POSITIVE and

NEGATIVE SUPPLY CIRCUIT BREAKERS are closed.

44

Install the AC Power Cable between the amplifier and your AC

mains outlet.

Note:

Note:

If the amplifier is to be moved to another location, always

place the unit in Standby mode before disconnecting the AC power

cable from the AC mains wall outlet.