Step3 setup, Procedure for setting the dip switch, Setup – JVC MC-R433U User Manual

Page 5

Advertising
background image

E

ENGLISH

<MC-R433U connection example>

1.

Connect the power supply cable, control cable and SCSI

cable to the connectors at the rear of the MC-R433U.
Ⅵ When using the MC-8100U, the No. of the cable must

always correspond to the No. of the drive bay to which it
is being connected. If a cable with the wrong number is
connedted, it will lead to the equipment malfunctioning.

Ⅵ When using the MC-8200U/8600U, connect power sup-

ply and control cables, which lead from the side of the

MC-R433U drive bay to the drive.

Ⅵ Insert all connectors firmly.
Ⅵ SCSI cables are connected as a daisy chain connec-

tion. Each connector should be connected to the drive
positions as illustrated in the diagram.

Ⅵ Terminate each point where the SCSI bus is terminated

physically.

• Setting of the built-in terminators

"Procedure for Setting the DIP Switch" on page 5

• Setting of the external terminators:

The use of active terminators is recommended.

1.

TERM: Selection of the use of built-in terminators.

Ⅵ When using the built-in terminators:

• With the MC-R433U unit located at a point where

the SCSI bus is physically terminated set its TERM
ON.

• With other MC-R433U units, set their TERMs to OFF.

Ⅵ When not using the built-in terminators:

• Attach external terminators to the OUT terminals of

the SCSI connector.

• When using an external terminator, set all of the

TERMs of the MC-R433U to OFF.

Ⅵ To improve the stability of SCSI bus communications, it

is recommended to use an active external terminator.

2.

ID2, ID1, ID0: Setting of the SCSI ID No. of each drive.

Ⅵ When setting the SCSI ID No., use a number that is not

being used by other SCSI devices on the same bus.

<MC-R433U rear panel>

<MC-R433U DIP switch settings on the rear panel>

DVD-RAM/R drive

Library SCSI board

DVD-RAM/R drive

DVD-RAM/R drive

(Terminate.)

●SCSI connector terminals
OUT 2 :Active terminator connected.
IN 2

:Connected to the host computer's

SCSI host adapter No. 2.

OUT 1 :Active terminator connected.
IN 1

:Connected to the host computer's

SCSI host adapter No. 1.

SCSI cable (Additional)

* Up to two DVD-RAM/R drives can

be connected.

SCSI cable (Standard)

Up to 6

*

1

drives can be connected.

(

*

1: Up to 4 with the MC-8100.)

SCSI-B

SCSI-D(F)

SCSI-C(E)

SCSI-A

OUT 2

OUT 1

IN 1

IN 2

SCSI connector

Procedure for Setting the DIP Switch

Set the SCSI ID of the MC-R433U and close the door
of the CD/DVD Library.

Always turn the power of the CD/DVD Library off when
the dip switches are moved.
For the details of the default factory settings, please
refer to the section "SCSI ID No. SETTING" of the
instructions from the CD/DVD Library.

SETUP

<SCSI ID No. and DIP switch settings>

*

: Factory setting.

SCSI ID No.

Switch

ID2

ID1

ID0

0

OFF

OFF

OFF

1

*

OFF

OFF

ON

2

OFF

ON

OFF

3

OFF

ON

ON

4

ON

OFF

OFF

5

ON

OFF

ON

6

ON

ON

OFF

7

ON

ON

ON

W

N

Power cable

Control cable

Slide switch

DIP switch

SCSI cable

14p

3

4p

2

3

1

N

W

ON

OFF

(Factory setting)

TERM

ID 2

ID 1

ID 0

ON

1

2

3

4

Procedure for Connecting the Cables to

the Back of the MC-R433U