7.2. CV-A50/60 RS-232C command list.

Command Name

Format

Parameter

Remarks

A – General settings and useful commands
EB
Echo Back

EB=[Param.]<CR><LF> 0=Echo off

1=Echo on

Off at power up

ST Camera Status request ST?<CR><LF>

Actual setting

HP Online Help request HP?<CR><LF>

Command list

VN Firmware version

VN?<CR><LF>

3 letter version

B – Timing and shutter related commands
SC
Scanning format

SC=[Param.]<CR><LF> 0=Interlaced

2=1/2 partial

1=Non-interl.

3=1/3 partial

Partial scanning is
not supported

TR Trigger mode

TR=[Param.]<CR><LF> 0=normal

2=Pulse width

4=Long time

1=Edge
3=Frame delay

5=Start/stop

SM Shutter mode

SM=[Param.]<CR><LF> 0=Normal 1=Programmab.

SH Shutter speed

SH=[Param.]<CR><LF> 0=Off

0=1/50 (1/60)
2=1/250

4=1/1000
6=1/4000

1=1/100

1=1/125
3=1/500

5=1/2000
7=1/10000

Continuous only


Trigger modes and

Continuous

PE Programmable expos.

PE=[Param.]<CR><LF> 0= No function

1023=1023.5H

1=1.5H

CCIR. H=64µsec
EIA, H=63.5µsec
*1)

C – Signals and polarity
FR
Accumulation

FR=[Param.]<CR><LF> 0=Field

1=Frame

PC Pixel clock

PC=[Param.]<CR><LF> 0=no clock out

1=clock out

Should be off
when not used

TP Trigger polarity

TP=[Param.]<CR><LF> 0= active low

1= active high

*2)

WP WEN polarity

WP=[Param.]<CR><LF> 0= active low

1= active high

D – Gain and analogue signals setting
AS
AGC Switch

AS=[Param.]<CR><LF> 0=AGC off

1=AGC on

0= manual gain

AG AGC Level

AG=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

GA Manual gain Level

GA=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

RP Rear Potentiometer

RP=[Param.]<CR><LF> 0=manual gain

1=rear potm.

SU Setup Level

SU=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

WC White clip Level

WC=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

GS Gamma Select

GS=[Param.]<CR><LF> 0=gamma 1

1=gamma 0.45

E – Saving and loading data in EEPROM
LD
Load settings from

camera EEPROM

LD=[Param.]<CR><LF> 0=Factory data

2=User 2 area

1=User 1 area
3=User 3 area

Latest used data
area becomes
default at next
power up

SA Save settings to

camera EEPROM

SA=[Param.]<CR><LF> 1=User 1 area

3=User 3 area

2=User 2 area


*1)

In normal non trigger mode (TR=0) PE<312 for CCIR and PE<262 for EIA. In trigger mode TR=1, EEN will not be correct if
PE>833.

*2)

If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.

!!

Do not try to use commands not shown in the list.