COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

UNIT MODEL

FURNACE**

COIL

MODEL

COOLING

CFM RANGE

(Min.-max.)

W

RATED

CFM

NET MBH

SEER

1

EER

TOTAL

SENS.

TCGD30S4(3,4)S1

800 - 1200

14

FC/MC/PC32

1000

29.0

21.0

13.00

11.00

800 - 1200

17,21

FC/MC/PC35

1000

29.0

21.0

13.00

11.00

800 - 1200

14

FC/MC/PC37

1000

29.0

21.0

13.00

11.00

800 - 1200

17,21

FC/MC/PC43

1000

29.0

21.0

13.00

11.00

800 - 1200

17

HC36

1000

29.0

21.0

13.00

11.00

800 - 1200

21

HC42

1000

29.0

21.0

13.00

11.00

TCGD36S4(3,4)S1

1000 - 1400

14

FC/MC/PC37

1200

35.0

24.8

13.00

11.00

1000 - 1400

17,21

FC/MC/PC43

1200

35.0

24.8

13.00

11.00

1000 - 1400

21,24

FC/MC/PC48

1200

35.0

24.8

13.00

11.00

1000 - 1400

21

HC42

1200

35.0

24.8

13.00

11.00

1000 - 1400

21,24

UC48

1200

35.0

24.8

13.00

11.00

TCGD42S4(3,4)S1

1200 - 1600

17,21

FC/MC/PC43

1400

42.0

29.2

13.00

11.00

1200 - 1600

21,24

FC/MC/PC48

1400

42.0

29.2

13.00

11.00

1200 - 1600

21

HC42

1400

42.0

29.2

13.00

11.00

1200 - 1600

21,24

UC48

1400

42.0

29.2

13.00

11.00

TCGD48S4(3,4)S1

1400 - 1800

21,24

FC/MC/PC48

1600

48.0

34.4

13.00

11.00

1400 - 1800

21,24

FC/MC/PC60

1600

48.0

34.4

13.00

11.00

1400 - 1800

24

HC60

1600

48.0

34.4

13.00

11.00

1400 - 1800

21,24

UC48

1600

48.0

34.4

13.00

11.00

1400 - 1800

21,24

UC60

1600

48.0

34.4

13.00

11.00

TCGD60S4(3,4)S1

1600 - 2000

21,24

FC/MC/PC60

1800

57.0

38.5

13.00

11.00

1600 - 2000

24

FC/MC62

1800

57.0

38.5

13.00

11.00

1600 - 2000

24

HC60

1800

57.0

38.5

13.00

11.00

1600 - 2000

21,24

UC60

1800

57.0

38.5

13.00

11.00

1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.