Applied system (b mode), Setting procedure, Connections – JVC RM-P2580 User Manual

Page 21: Master monitor monitor timelapse vcr, Id:1 id:2 id:3, Rm-p2580, V.in, Camera 1 camera 2 camera 3, Set pin 1 to "on" for b mode, Preset positions ( ref. : page 27)

Advertising
background image

21

V.IN

V.IN

3

4

2

1

MONITOR B
OUTPUT

CAM SW

OUT

VIDEO
INPUT

CAM

IN

MONITOR-A

OUTPUT

VCR
OUTPUT

RS-232C

MASTER MONITOR

MONITOR

TIMELAPSE VCR

CAMERA 1

CAMERA 2

CAMERA 3

ID:1

ID:2

ID:3

5 6 7 8

1

TO CAMERA

TO CAMERA

DATA I / O

DATA I / O

RX

RX+ RX

RX- TX

TX+ TX

TX-

COM

COM

1

2

3

4

5

6

7

8

COM

COM 9/1

9/1 10/2

10/2 11/3

11/3 12/4

12/4 13/5

13/5 14/6

14/6 15/7

15/7 16/8

16/8 COM

COM

COM

COM

COM

COM

CAMERA

CAMERA

SW

SW

UNIT

UNIT

ALARM

ALARM

AUTO

AUTO

4

3

1 2

8

7

5 6

2

3

4

5

6

7

8

1

MONITOR

OUTPUT

MONITOR

SERIAL-2

SERIAL-2

SERIAL-1

SERIAL-1

VIDEO INPUT

VIDEO INPUT

VIDEO OUTPUT

VIDEO OUTPUT

OUTPUT

2

1

ON

2

3

4

5

6

7

8

POWER

OFF

ON

AC INPUT

`

REC

REC

STOP

REC

CHECK

EJECT

OPERATE

OPERATE

AC24V

AC24V

AC24V

MONITOR
OUTPUT 1

VIDEO
INPUT 1

SEREAL-2

TO

CAMERA

RM-P2580

Set Pin 1 to "ON" for B Mode.

4. CONNECTIONS

APPLIED SYSTEM (B MODE)

<The compatible frame switchers are SW-D7000 and SW-D8000.>

This system accepts the connection of up to 16 cameras.
The video is recorded by means of a frame switcher.

Setting Procedure

1.

Connect all the equipment.
(All of the cameras must be synchronized)

2.

Set the system mode selection to B Mode, and set the rear DIP SW1
to "ON".

3.

To set a camera ( REF. : Instruction Manual of the camera being
used)
· Match the ID with the VIDEO INPUT number.
· Set to MULTIDOROP and DUPLEX

4.

Using the SERIAL-2 item, set to the frame switcher. ( REF. : page 29)

5.

Set the alarm to the PRIORITY mode for alarm signal input.
Set the " PRIORITY" in the ALARM SCREEN to “ALARM”.
( REF. : page 32)

6.

Frame switcher setting

Set the Baud rate to 9600 bps.
Set the SW-D7000/SW-D8000 communications menu of RS232 to
9600 bps.

Set the alarm time to that of RM-P2580.
Adjust the Alarm timeout of the timeout menu inside the alarm latch
menu of SW-D7000/SW-D8000 to the ALARM TIME of RM-P2580.

7.

Preset positions ( REF. : page 27)

8.

Operational setting values can be changed as required.
· P/T SPEED: 8 STEPS ( REF. : page 29)

9.

Check the ALARM INPUT time set value.
· DATA I/O screen: 16ALM IN or 8 ALM IN ( REF. : page 30)
· ALARM screen ( REF. : page 32)

10

.

ALARM INPUT TIME setting required for each camera
· TERMINAL item ( REF. : page 31)

When an alarm input is required to the SW-D7000/
SW-D8000, be sure to use the ALM OUTPUT of
the I/O terminal of RM-P2580.

Read the "Instruction Manual" for each piece of
equipment to be connected before performing the
connection.

NOTES

When the +, -, Auto, F1~3 buttons are
pressed quickly and consecutively, it may
happen that the camera display does not
correspond to the video output. If this is the
case, press the buttons slowly and precisely.

The AUTO LED of the RM-P2580 will not light
up, even during AUTO SEQUENCE.

When connecting a frame switcher, be sure to read its
"Instruction manual" before connecting it.

RM-P2580 SERIAL-2 connector
(D-sub 9 pin, female)

SW-D7000/SW-D8000 Alarm connector
(D-sub 9 pin, male)

Pin No.

Signal name

R X D

T X D

G N D

2
3
5

Pin No.

Signal name

R X

T X

G N D

2
3
5

Advertising