Electrical connection, Permanent connection – John Lewis JLTDC 05 User Manual

Page 8

Advertising
background image

8

Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person

.

WARNING: THIS APPLIANCE MUST

BE EARTHED.

The manufacturer declines any liability

should this safety measure not be
observed.
Should the appliance power supply cable
need to be replaced, this must be carried
out by by a Service Force repair agent (Pg
18 service and spare parts)

Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance’s
rating plate. (See picture on page 5).

The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved BS 1363/A fuse must
be used.
Should the plug need to be replaced for any reason, proceed
as described below. The wires in the mains lead are
coloured in accordance with the following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

The wire coloured green and yellow must be connected

to the terminal marked with the letter «E» or by the

earth symbol

or coloured green and yellow.

The wire coloured blue must be connected to the

terminal «N» or coloured black.

The wire coloured brown must be connected to the

terminal marked «L» or coloured red.

GREEN & YELLOW

BROWN

CORD CLAMP

BLUE

13

A

P1041

E

N

L

Electrical connection

Upon completion there must be no cut, or stray strands

of wire present and the cord clamp must be secure over

the outer sheath.

WARNING:

A cut off plug inserted into a 13 amp
socket is a serious safety (shock)
hazard.

Ensure that the cut off plug is disposed of
safely.

Permanent connection

In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap of
3mm between the switch contacts and of a type suitable
for the required load in compliance with the current
electrical regulations.

The switch must not break the yellow and green earth
cable at any point.