Installation, Electrical requirements, Electrical connection – John Lewis JLBIOS601 User Manual

Page 5: For uk use only, Heating elements rating

Advertising
background image

5

THIS O

THIS O

THIS O

THIS O

THIS OVEN MUST BE EAR

VEN MUST BE EAR

VEN MUST BE EAR

VEN MUST BE EAR

VEN MUST BE EARTHED

THED

THED

THED

THED

Electrical Requirements

Electrical Requirements

Electrical Requirements

Electrical Requirements

Electrical Requirements

Any permanent electrical installation must comply with the
latest I.E.E. Regulations and local Electricity Board regulations.
For your own safety this should be undertaken by a qualified
electrician, e.g. your local Electricity Board, or a contractor
who is on the roll of the National Inspection Council for
Electrical Installation Contracting (NICEIC).

Electrical Connection

Electrical Connection

Electrical Connection

Electrical Connection

Electrical Connection

The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
Before connecting to the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate on
the side of the oven door.
The oven has an easily accessible terminal block which is
marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

The cable used to connect the oven to the electrical supply
must comply to the specifications given below.

Electrical Connection

Electrical Connection

Electrical Connection

Electrical Connection

Electrical Connection

It is necessary that you install a double pole switch between
the oven and the electricity supply (mains), with a minimum
gap of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the current
rules.

The switch must not break the yellow and

The switch must not break the yellow and

The switch must not break the yellow and

The switch must not break the yellow and

The switch must not break the yellow and
green earth cable at any point.

green earth cable at any point.

green earth cable at any point.

green earth cable at any point.

green earth cable at any point.

It is necessary that the yellow/green earth

It is necessary that the yellow/green earth

It is necessary that the yellow/green earth

It is necessary that the yellow/green earth

It is necessary that the yellow/green earth
wire is about 2 cm longer than the live and

wire is about 2 cm longer than the live and

wire is about 2 cm longer than the live and

wire is about 2 cm longer than the live and

wire is about 2 cm longer than the live and
neutral ones.

neutral ones.

neutral ones.

neutral ones.

neutral ones.

Important

Important

Important

Important

Important

After installation and connecting, the cable must be placed
so that it cannot at any point reach a temperature of more
than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and
the domestic installation can support the load; and that the
power supply is properly earthed.

The manufacturer disclaims any responsibility should these
safety measures not be carried out.

Connection

Connection

Connection

Connection

Connection

Min. size

Min. size

Min. size

Min. size

Min. size

Cable / flex

Cable / flex

Cable / flex

Cable / flex

Cable / flex Fuse

Fuse

Fuse

Fuse

Fuse

v i a

v i a

v i a

v i a

v i a

Cable/flex

Cable/flex

Cable/flex

Cable/flex

Cable/flex type

type

type

type

type

• Cooker

2.5 mm

2

PVC/PVC

20 A

Control

twin and

Circuit

earth

For UK use only

For UK use only

For UK use only

For UK use only

For UK use only

FFFFFor Eur

or Eur

or Eur

or Eur

or Europe use onl

ope use onl

ope use onl

ope use onl

ope use onlyyyyy

Min. size Cable/flex

Min. size Cable/flex

Min. size Cable/flex

Min. size Cable/flex

Min. size Cable/flex

Cable / flex type

Cable / flex type

Cable / flex type

Cable / flex type

Cable / flex type

Fuse

Fuse

Fuse

Fuse

Fuse

2.5 mm

2

H07 RN-F, H05 RN-F, 15 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F

T

T

T

T

Technical Data

echnical Data

echnical Data

echnical Data

echnical Data

Dimensions of recess

Dimensions of recess

Dimensions of recess

Dimensions of recess

Dimensions of recess

Height

580 mm

Width

560 mm

Depth

550 mm

Dimensions of the o

Dimensions of the o

Dimensions of the o

Dimensions of the o

Dimensions of the ovvvvven ca

en ca

en ca

en ca

en cavity

vity

vity

vity

vity

Height

335 mm

Width

395 mm

Depth

400 mm

Oven capacity

53 litres

Installation

Installation

Installation

Installation

Installation

Heating elements rating

Heating elements rating

Heating elements rating

Heating elements rating

Heating elements rating

Fan Oven

2,000 W

Grill element

1,650 W

Convection Fan

25 W

Oven Light

25 W

Cooling Fan

25 W

Total Rating

2,050 W

Supply voltage (50 Hz)

230 V

Advertising