If you fit your own plug, the colours of the
wires in the mains lead of your appliance
may not correspond with the markings
identifying the terminals in your plug.
Proceed as follows:
1. Connect the Green and Yellow (earth)

wire to the terminal in the plug which is
marked with the letter "E" or the earth
symbol or coloured green and
yellow.

2. Connect the Blue (neutral) wire to the

terminal in the plug which is marked
with the letter "N" or coloured black.

3. Connect the Brown (live) wire to the

terminal in the plug which is marked
with the letter "L" or coloured red.

4. Upon completion there must be no cut,

or stray strands of wire present and the
cord clamp must be secure over the
outer sheath.

Warning! A cut off plug
inserted into a 13 amp socket is
a serious safety (shock) hazard.
Ensure that the cut off plug is
disposed of safely.

Warning! The plug must still be
accessible after the appliance
has been installed.

Warning! The appliance should
not be connected to the
electrical supply by means of an
extension cable.

Warning! The manufacturer
declines any responsibility for
damage or injury through
failure to comply with the
above safety precautions.
Should the appliance power
supply cable need to be
replaced, this must be carried
out by our Service Centre.

Warning! The power supply
cable must be accessible after
installing the machine.

Permanent connection

In the case of permanent connection it is
necessary that you install a double pole
switch between the appliance and the
electricity supply (mains), with a minimum
gap of 3mm between the switch contacts
and of a type suitable for the required load
in compliance with the current electrical
regulations.
The switch must not break the yellow and
green earth cable at any point.

Door reversal

To make it easier to load or unload the
laundry, the door can be reversed.

Warning! Before changing the door
stop, disconnect the mains plug: with
a permanent connection: fully
unscrew or deactivate the fuse.

1. Open loading door.
2. Unscrew hinge A from the front of the

machine and take off the loading door.

3. Remove cover plates B. To do this,

insert a thin screwdriver into the slots
as shown in the illustration, press
downwards slightly and pry out the
cover plates.

25