Jøtul gi 425 camden direct vent gas fireplace, Accessories, 4specifications – Jotul GI 425 DV User Manual

Page 4: Test standards

Advertising
background image

4

Specifications

Input Rates

Natural Gas

26,000 BTU/hr. maximum input
13,000 BTU/hr. minimum input

Propane

26,000 BTU/hr. maximum input
13,000 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas: 5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane: 12.0 WC (2.98 kPa) 14.0 WC (3.48 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas: 1.2 WC (0.29 kPa)

3.8 WC (0.95 kPa)

Propane: 2.9 WC (0.72 kPa) 11.0 WC (2.74 kPa)

Steady State Efficiency: 77.3%
A.F.U.E. Efficiency: 67.9%
Piezo Ignitor / Standing Pilot

Jøtul GI 425 Camden

Direct Vent Gas Fireplace

Manufactured and Distributed by:

Jøtul A.S.A.

Fredrikstad, Norway

Jøtul North America

Gorham, Maine

Test Standards

This appliance complies with
National Safety standards and
is tested and listed by Intertek
Testing Services of Middleton,
Wisconsin.

In addition, the Jøtul GI 425 DV gas fireplace

insert has been tested and listed as a direct vent gas
fireplace heater and listed to ANSI Z21.88-1998
(NFPA 54) and CSA 2.33-M98 for Canada.

Antique Brick Panel Kit ....................................... #155311
Wide Surround Kit - Cast Iron
Max. Opening Overlap: 47” Wide x 33 1/2” High.

Matte Black ................................................... #155323
Blue Black Enamel ....................................... #155324
Jøtul Iron Gray .............................................. #155354

Fuel Conversion Kit - NG to LP ......................... #155300
Fuel Conversion Kit - LP to NG ......................... #155303
Wall Thermostat ................................................... #750003
Remote Control ..................................................... #129706

Jøtul QuickFace™ System

Rectangular Frame w/ Screen,

Brushed Stainless Steel ............................. #155312

Arched Frame w/ Screen,

Brushed Stainless Steel ............................. #155313

Rectangular Frame w/ Screen,

Matte Black ................................................... #155314

Arched Frame w/ Screen,

Matte Black ................................................... #155315

Double Doors, Cast Iron -

Matte Black ................................................... #350565

Double Doors, Cast Iron -

Blue Black Enamel ....................................... #350566

Accessories

Suggested Tools for
Installation and Service

• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve - T-Handle in Massachusetts
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10mm open end wrench
• 1/2”, 7/16” open end wrench
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution
• Power Drill

THIS FIREPLACE IS SHIPPED AS A N

N

N

N

NA

A

A

A

ATURAL

TURAL

TURAL

TURAL

TURAL

GAS

GAS

GAS

GAS

GAS FIREPLACE ONLY. IF USE WITH PRO-

PANE IS DESIRED, THE FIREPLACE MUST BE

CONVERTED TO USE WITH PROPANE. FOR

YOUR CONVENIENCE THIS FIREPLACE IS

SHIPPED WITH A PROPANE CONVERSION

KIT.

MEA No. 369-04-E

Advertising