7

For optimal grounding, we recommend the
use of a JL Audio ECS master ground lug
(XB-MGLU). Alternatively, a sheet metal
screw or bolt can be used with a star washer.

Many vehicles employ small (10 AWG - 6 AWG)

wire to ground the battery to the vehicle chassis

and to connect the alternator’s positive

connection to the battery. To prevent voltage

drops, these wires should be upgraded to 4

AWG pure copper wire when installing amplifier

systems with main fuse ratings above 60A.

turn-on wire

The HD900/5 uses a conventional +12V remote

turn-on wire, typically controlled by the source
unit’s remote turn-on output. The amplifier will
turn on when +12V is present at its “Remote”
input and turn off when +12V is switched off. If
a source unit does not have a dedicated remote
turn-on output, the amplifier’s turn-on lead can
be connected to +12V via a switch that derives
power from an ignition-switched circuit.

The HD900/5’s “Remote” turn-on connector

is designed to accept 18 AWG – 12 AWG wire. 18
AWG is more than adequate for this purpose.
To connect the remote turn-on wire to the
amplifier, first back out the set screw on the
bottom of the Power Connector Plug, using the
supplied hex wrench. Strip 1/2 inch (12mm) of
wire and insert the bare wire into the receptacle,
seating it firmly so that no bare wire is exposed.
When using smaller wire, it may be necessary to
strip 1 inch of insulation from the wire and fold
the bare wire in half prior to insertion. While
holding the wire in the terminal, tighten the
set screw firmly using the supplied 2.5 mm hex
wrench, taking care not to strip the head of the
screw and making sure that the wire is firmly
gripped by the set screw.

amplifier Power connector Plug

To connect the power wires and the remote

turn-on wire to the amplifier, unplug the power
connector plug from the amplifier chassis (pull
back firmly) and back out the set screws on
the connector plug, using the supplied 4 mm
hex wrench for the +12 VDC” and “Ground”
connections and the supplied 2.5 mm hex wrench
for the “Remote” connection. Strip 3/8 inch (10
mm) of insulation from the end of each wire and
insert the bare wire into the receptacle on power
connector plug, seating it firmly so that no bare
wire is exposed. While holding each wire in place,
tighten each set screw firmly, taking care not to
strip the head of the screw.

Never make power connections with a “live”

wire. Always disconnect the negative battery

post before making any connections or

adjustments to a 12V power connection!