RATINGS CHART – OIL BOILERS

©Slant/Fin Corp. 2007

®

INTREPID TR SERIES - WATER

*

Add Suffix: (P)Packaged water boiler less tankless heater, (PT)Packaged water boiler with tankless heater, (PPT)Packaged water boiler with provision for tankless heater, (PZ)Packaged steam boiler less
tankless heater, (PZT)Packaged steam boiler with tankless heater.

Ratings apply to the use of light oil at 140,000 Btu per gallon, and a .02% draft (negative pressure) over the fire.

The net I=B=R output ratings shown are based on an allowance for piping and pickup of 1.15 (water) or 1.33 (steam). D.O.E. capacity gross output is divided by the allowance to obtain net rating.
The manufacturer should be consulted before selecting a boiler for unusual piping and pickup requirements such as intermittent system operation, extensive piping, etc.

§

Nominal clay tile liner dimensions.

** Tankless heater rating based on intermittent draw.

Water boiler models TR-30, TR-40, TR-50, TR-60 and TR-70 have two firing rates. The boiler is factory shipped at the lower firing rate. To obtain the higher firing rate, refer to the Intrepid boiler installation
instructions for the appropriate field adjustments.

#

I.B.R. gross output

∆ Collar is oblong, will fit 6" diameter nominal connector.

NOTE: All boilers under 300,000 Btuh input are tested and rated for capacity under the U.S. Department of Energy (D.O.E.) Test Procedures for Boilers.å

TR-20

0.75

105,000

91

79

8 x 8 x 15

5 x 15

83.50

11

1

2

8

9

32

6

1

1

4

24

1

4

2

2.20

TR-30H

1.00

140,000

121

105

8 x 8 x 15

6 x 15

86.00

14

7

8

10

1

32

6

1

1

4

27

5

8

3

3.00

TR-30

1.10

154,000

134

134

117

101

421

8 x 8 x 15

6 x 15

84.85

84.15

14

7

8

10

1

32

6

1

1

4

27

5

8

3

3.20

3.00

1.25

175,000

151

131

8 x 8 x 15

6 x 15

83.50

14

7

8

10

1

32

6

1

1

4

27

5

8

3

3.40

TR-40H

1.50

210,000

182

179

158

134

558

8 x 8 x 15

6 x 15

86.00

84.00

18

1

4

11

23

32

7

1

1

4

31

4

3.80

3.40

TR-40

1.60

224,000

195

195

170

146

608

8 x 8 x 15

7 x 15

84.45

83.80

18

1

4

11

23

32

7

1

1

4

31

4

3.90

3.50

1.80

252,000

218

190

8 x 8 x 15

7 x 15

83.33

18

1

4

11

23

32

7

1

1

4

31

4

4.15

TR-50H

2.00

280,000

243

239

211

179

746

8 x 8 x 15

7 x 15

86.00

84.00

21

5

8

13

13

32

8

1

1

2

34

3

8

5

4.40

3.90

TR-50

2.10

294,000

256

255

223

191

796

8 x 8 x 15

8 x 15

84.06

83.45

21

5

8

13

13

32

8

1

1

2

34

3

8

5

4.40

4.00

2.35

329,000

272

#

237

8 x 12 x 15

8 x 15

21

5

8

13

13

32

8

1

1

2

34

3

8

5

4.70

TR-60

2.60

364,000

298

#

298

#

259

224

933

8 x 12 x 15

10 x 15

25

15

3

32

8

1

1

2

37

3

4

6

4.90

4.50

2.85

399,000

327

#

284

8 x 12 x 15

10 x 15

25

15

3

32

8

1

1

2

37

3

4

6

5.20

TR-70

3.10

434,000

352

#

354

#

306

266

1108

8 x 12 x 15

10 x 15

28

3

8

16

25

32

9

41

1

8

7

5.45

5.00

3.35

469,000

381

#

331

8 x 12 x 15

10 x 15

28

3

8

16

25

32

9

41

1

8

7

5.70

Boiler
Model

No.

I=B=R Burner

Capacity

Oil Input

GPH

BTUH

D.O.E.

Heating

Capacity

MBH

Water Steam

I=B=R Burner

Net Ratings

Water
MBH

Steam

MBH

Steam
Sq. Ft.

I=B=R Chimney Size

Nom. Rect.

x Height

§

(in x in x ft)

I.D.Round

x Height

(in x ft)

A.F.U.E.

%

Water Steam

Dimensions (inches)

Boiler

Length

“A”

Front to

Flue ¢

“B”

Flue

Dia.
“C”

Return

Circulator

Flange

“D”

Overall
Length

“E”

Boiler

section

Tankless

Heater

GPM

**

Water

Steam