Connection, Using coaxial communications, Soc-416 0 – Samsung SOC-4160 User Manual

Page 8: Connecting to rs-485 control cable, Rs-485 communication control

Advertising
background image

COLOR CCD CAMERA

User Guide

14

COLOR CCD CAMERA

User Guide

15

• When making a control system to control the camera, please use to the

protocol(STW(SPD), PELCO-P, PELCO-D, VICON, PANASONIC, BOSCH, HONEYELL, SEC).

• When you connecting to RS-485 CONTROL TERMINAL, please peel off the outer

skin inside the RS-485 CONTROL TERMINAL.

• In case of SCC-101 connection, change communication mode to

8-E-1

at

Communication

configuration

menu. (For more information, refer to SCC-101 manual.)

Notes

Using Coaxial Communications

DVD

SOC-416

0

• Coaxial Communications System

• OSD Control method

DVR

Distance

Recommended Cable Specification

300m

3C2V(RG-59/U)

450m

5C2V(RG-6/U)

600m

7C2V(RG-11/U)

– Video Cable
The camera's video output port is connected to the monitor with a BNC coaxial cable,

shown below : If the distance between the camera and the monitor exceeds the
recommended maximum, please use an auxiliary video amp.

• If the camera is controlled through coaxial communication, please use a video amp

intended for coaxial communications. Regular video amps do not transfer coaxial
signals.

Notes

Using RS-485 communication will enable you to control the OSD menu from a SAMSUNG
TECHWIN System Controller or DVR.
(1) Connection to a PC.

Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.

EX) SERIAL PORT OF THE PC(COM1) → SERIAL CABLE → RS-485 CONVERTER → RS-485

CONTROL CABLE

Connecting to RS-485 Control Cable

CONTROL CABLE

SPEC

WHITE (TRX+)

RS-485+

BLCAK (TRX-)

RS-485-

* RS-485 Communication establishment initial value

485 Control Board Connection Port

RS-485 Control Port

(+) CONNECTION TERMINAL

WHITE (TRX+)

(-) CONNECTION TERMINAL

BLACK (TRX-)

Item

Camera ID

BAUD RATE

UART MODE

RET PKT

Initial value

1

9600

8-NONE-1

ENABLE

(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.

WHITE (TRX+)

BLACK (TRX

-)

CAMERA

DVR

CONTROLLER

SET

MENU/ENTER

OSD KEY

UP

UP KEY

JOYSTICK UP

DOWN

DOWN KEY

JOYSTICK DOWN

LEFT

LEFT KEY

JOYSTICK LEFT

RIGHT

RIGHT KEY

JOYSTICK RIGHT

RS-485 communication control

Connection

: BNC

• ---- : RS-485

Advertising