STA-RITE SR-6000 User Manual

Page 2

Advertising
background image

2

TABLE OF CONTENTS

Safety ..................................................................2
Description .........................................................2
Application .........................................................3
Installation ......................................................3, 4
PCA Control Layout........................................4, 5
Control Description.........................................5-7
Maintenance.......................................................7
Repair Parts.....................................................8, 9
Warranty...........................................................12

READ AND FOLLOW
SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this

symbol on your system or in this manual, look for

one of the following signal words and be alert to the po-
tential for personal injury.

warns about hazards that will cause death,

serious personal injury, or major property damage if
ignored.

warns about hazards that can cause death,

serious personal injury, or major property damage if
ignored.

warns about hazards that will or can cause

minor personal injury or property damage if ignored.
NOTICE indicates special instructions not related to
hazards.
Carefully read and follow all safety instructions in this
manual and on equipment.
Keep safety labels in good con-
dition; replace if missing or damaged.

Incorrectly installed or tested equipment
may fail, causing severe injury or property
damage.
Read and follow instructions in

owner's manual when installing and operating equipment.
Use equipment only in a pool installation.

Explosion hazard. This feeder is not

explosion proof. Do not install or use in an explosive
atmosphere.

DESCRIPTION

The SR-4000 and the SR-6000 are liquid dispensing sys-
tems for pool and spa applications consisting of a peri-
staltic pump, an interval timer and a duration timer. With
the flexibility of interval choices as well as duration adjust-
ment, they are capable of handling a range of applications.
The SR-4000 is a single pump system. The SR-6000 is a
dual pump system, with a separate control board for each
pump. Either system can be plugged into a standard
115VAC electrical outlet with the cord provided or hard-
wired to 115VAC, 208VAC, or 230 VAC using the wiring
diagrams provided (See Figure 3, Page 3).

PUMP

Pump Activate
LED

115 VAC
Power Cord

OFF-ON
Toggle Switch

Pump Tube with
Connector Tubes

Model 300
Pump Assembly

SR

– 4000

Single Pump Chemical System

3967 0501

PUMP 1

PUMP 2

Pump Tube with
Connector Tubes

Pump Tube with
Connector Tubes

SR

– 6 000

Dual Pump Chemical System

Model 300 Pump
Assembly

Model 300 Pump
Assembly

Pump 2 Activate LED

Pump 1 Activate LED

Pump 2 OFF-ON
Toggle Switch

Pump 1 OFF-ON
Toggle Switch

Pump 2 115 VAC
Power Cord

Pump 1 115 VAC
Power Cord

3968 0501

Figure 1: SR-4000 and SR-6000 chemical Feed
Systems.

Dispensers carrying the NSF seal are listed for swimming pools, spas and
hot tubs with the following chemicals:
12.5% SODIUM HYPOCHLORITE

10% HYDROCHLORIC ACID

80% NATURAL ENZYME

When proper materials are selected, they are capable of handling but not
limited to the following solutions:
12.5% ALUMINUM SULPHATE

5% SODIUM CARBONATE

2% CALCIUM HYPOCHLORITE

10% SODIUM HYDROXIDE

Advertising
This manual is related to the following products: