8 setting the self cleaning cycle, 9 during and after the self cleaning cycle, Instructions for the user – Smeg SCP111BU2 User Manual

Page 24

Advertising
background image

Instructions for the user

26

8.8

Setting the self cleaning cycle

1 With the oven ON, use PT2 to select the self cleaning function.

2 To start the self cleaning cycle, press knob PT1 twice to set its

duration.

3 Turn knob PT1 to the right or left to increase or decrease the cycle

duration between a minimum of 1h 30m and a maximum of 3h 00m.

4 The message "CLEA" will appear on DSP1 to indicate that the oven

is performing the cleaning cycle.

5 The time remaining until the end of the cleaning cycle will be shown

on DSP1.

8.9

During and after the self cleaning cycle

Two minutes after the self cleaning cycle, an interlock device will
activate, preventing the door from being opened. The symbol lights on
DSP2 to indicate that this interlock device has been activated.

At the end of the cleaning cycle the door interlock device will remain
active until the temperature inside the oven has reached a safety
threshold. When the oven has cooled down, remove the residues from
the automatic cleaning cycle with a damp micro-fibre cloth.

Once the door interlock has been activated, no oven functions can be selected.

Wait for the

symbol to turn off.

8.10 Setting the self cleaning cycle with delayed start

1 Repeat steps 1, 2 and 3 described in “8.8 Setting the self cleaning

cycle”.

2 After setting the duration, press PT1 once. The symbol and the

current time will appear on the display.

3 Turning PT1 to the right increases the time, allowing the desired

cooking start time to be set.

4 A few seconds after the desired duration is set, the symbols stay on,

and the oven will start to wait for the starting time setting for the
cleaning cycle.