LS 400Xi Product Reference Guide

Technical Specifications

Table 4-1. Technical Specifications

Item

Description

Power Requirements*

IBM 46XX/Synapse
RS-232C/Synapse
Low Power

4.8 to 14 VDC (max) 200 mA @ 5V typical
4.8 to 14 VDC (max) 180 mA @ 5V typical
4.8 to 14 VDC (max) 2 mA @ 5V typical

Decode Capability

The LS 400Xi can be programmed to decode the following
code types: UPC/EAN, Bookland EAN, Code 39, Code
39 Full ASCII, Trioptic Code 39, Code 93, Codabar,
Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5,
MSI Plessey, and PDF417. Set code length(s) for any linear
code type. The LS 400Xi can auto-discriminate between all of
the above code types except for Code 39 and Code 39 Full
ASCII. Transmission of decoded information will depend on
the capabilities of the attached terminal.

Beeper Operation

User-selectable: Enabled, Disabled

Scan Repetition Rate

100 scans/sec (bidirectional)

Scan Angle

30°

Roll (Skew) Tolerance

± 10˚ from normal

Pitch

± 65˚ from normal

Yaw

± 60˚ from normal

1-D Decode Depth of Field

See

LS 400Xi 1-D Decode Zone on page 4-4

2-D Decode Depth of Field

See

LS 400Xi 2-D Decode Zone on page 4-5

Print Contrast Minimum

20% absolute dark/light differential, measured at 675 nm.

*For direct host power connection, make sure the host terminal supplies sufficient power for the
specified operation. Symbol is not responsible for damage to host equipment or system mis-
operation due to an insufficient power condition.