Schumacher SC-8020A User Manual

Page 10

Advertising
background image

8

COMpLETiON OF ChARgiNg:

11.5

12V Standard Battery:

Charge completion is indicated by the

CHARGED (green) LED; when lit, the charger has stopped charging and

switched to the Maintain Mode of operation.
12V AgM OR gEL CELL BATTERy:

The CHARGED LED comes on

when the battery is charged enough for normal use. After charging is

complete, the CHARGED LED will be on and the voltage will be less than

14V.

MAiNTAiN MODE

11.6

: When the CHARGED (green) LED is lit, the charger

has started Maintain Mode. This mode of operation is also known as Float-

Mode Monitoring. In this mode, the charger keeps the battery fully charged

by delivering a small amount of current, when necessary. The voltage is

maintained at a level determined by the BATTERy TyPE selected.
NOTE: For 12V AGM and 12V GEL CELL battery types, the CHARGED

LED might be lit before the maintain mode is started.
gENERAL ChARgiNg NOTES:

11.7

The charger is designed to control its cooling fan for efficient operation,

but the fan might run continuously when maintaining a fully charged bat-

tery. The fan does not run in Tester Mode.
If the charge mode is changed after charging has started (by pressing

the BATTERY SIZE or BATTERY TYPE button), the charging process will

restart.
The voltage displayed during charging will usually be higher than the bat-

tery’s resting voltage.
The voltage displayed during charging is the battery voltage, not the RMS

charging voltage.