no leakage and chamber is in operational condition. If the

chamber deflates, immediately bring to a Stearns certified

Repair Facility for repair. The device is no longer in

operational condition.

3. Automatic Inflation System – This test should be performed

during years when the PFD is not inspected by a certified

repair facility. With device packed as normal, immerse the

device into a tub of water and see if it inflates. DRY, REARM

and REPACK as shown on back cover of pamphlet.

4. Function Test of Oral Valve - Remove the dust protection

cap. With the PFD inflated, test the valve by pushing it down

using the tab provided on the cap (refer to page 9). The valve

should depress easily, and when released it should

automatically return to the closed position and reseal.

REARMING OF INFLATOR MECHANISM

Use Replacement Kit No. 0920 and 0923. See Rearming

Instructions on back cover for details.

CARE AND CLEANING INSTRUCTIONS

Drying – If the device is wet, place on a coat hanger to allow

thorough drying. Do not place in direct sunlight to dry. Do not

use any heat source or place on radiator.
Cleaning – Damp wipe only with mild detergent recommended

for synthetic fabrics. Remove grease and oil immediately.

After every use, remove pill (prior to rinsing) and rinse well

with fresh water. Read instructions provided on the device.

DO NOT MACHINE WASH

DO NOT MACHINE DRY

DO NOT DRY CLEAN

DO NOT USE SOLVENT BASED CLEANERS

DO NOT BLEACH

STORAGE

STORE YOUR PILLS (WATER SENSING ELEMENTS)

IN A VENTILATED PACKAGE, DO NOT STORE IN A
SEALED CONTAINER.

STORE IN CLEAN, COOL, DRY AREA.