Instruction for the installer, G30/g31, Mbar – Smeg JGB95XD1S User Manual

Page 8: Natural gas

Advertising
background image

Instruction for the installer

32

3.2 Burner and nozzle characteristics table (60 cm. models)

Burner

Rated

heating

capacity

(kW)

LPG

G30/G31

28/37

mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary

1.0

50

30

350

73 71

Semi-rapid

1.75

65

33

450

127 125

Rapid (3)

3.0

85

45

800

218 214

Rapid (5)

2.3

75

45

800

167 164

Triple crown

3.2

91

65

1500

233 229

Oven

3.2

87

48

850

233 229



Burner

Rated

heating

capacity

(kW)

NATURAL GAS –

G20

20

mbar

Nozzle diameter

1/100 mm

Reduced Flowrate

(W)

Auxiliary

1.0

72

350

Semi-rapid

1.75

97

450

Rapid (3)

3.0

115

800

Rapid (5)

2.3

103

800

Triple crown

3.5

133

1500

Oven

3.2

130

850