Instruction for the installer – Smeg JGB95XD1S User Manual

Page 9

Advertising
background image

Instruction for the installer

33

3.3 Burner and nozzle characteristics table (90 cm. models)


Burner

Rated

heating

capacity

(kW)

LPG

G30/G31

28/37

mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary

1

50

30

350

73

71

Semi-rapid

1.75

65

33

450

127

125

Rapid

3

85

45

800

218

214

Triple crown

3.2

91

65

1500

233

229

Fish pan

1.9

68

45

800

138

136

Oven

3.2

87

48

850

233

229

Maxi oven

5.2

110

59

1200

378

371

Grill

2.9

87

//

//

218

214

Maxi grill

4.0

100

//

//

291

286





Burner

Rated

heating

capacity

(kW)

NATURAL GAS –

G20

20

mbar

Nozzle diameter

1/100 mm

Reduced Flowrate

(W)

Auxiliary

1

72

350

Semi-rapid

1.75

97

450

Rapid

3

115

800

Triple crown (4)

3.5

133

1500

Triple crown (8)

3.5

140

1500

Fish pan

1.9

94

800

Oven

3.2

130

850

Maxi oven

5.2

164

1200

Grill

2.9

130

//

Maxi Grill

4.0

150

//

Advertising