CLOSING ELEMENT

• The space between the edge of the hood and

the rear wall can be closed by applying the
element 20 provided, using the screws supplied
for this purpose.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 mm, the choice of which is left to the installer.

• Fix the pipe in position using sufficient pipe

clamps (not supplied).

• Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

• Cut a hole ø 150 mm in the wall unit over the

hood.

• Connect the hood body outlet to the top part of

the wall unit using a rigid or flexible pipe ø 150
mm, to be selected by the installer.

• Fix the pipe in position using sufficient pipe

clamps (not supplied).

• Ensure that the activated charcoal filters have

been inserted.

ELECTRICAL CONNECTION

• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
• When opening the sliding carriage for the first time after installing the hood, pull it out briskly

until it clicks.