Roubleshooting – Southbend 436D User Manual

Page 41

Advertising
background image

M

ODEL

400 R

ESTAURANT

R

ANGES

T

ROUBLESHOOTING

O

PERATOR

S

M

ANUAL

1182299

REV

3 (05/05) D

RAFT

P

AGE

41

OF

64

TROUBLESHOOTING

Yes

No

Remove the upper valve panel

cover screws and tilt the panel

forward to expose the back of

blower switch.

CAUTION! WIRING BEHIND THE

PANEL OF THE NEXT STEP.

Remove the control knobs from the

range.

REMOVE THE MAIN POWER

SOURCE. UNPLUG OR

DISCONNECT CIRCUIT

BREAKER.

Check that the wires and terminals

are secure on the switch.

Remove the protective cover from

over the switch.

Place a DVM on the end terminals

of the blower switch wires 1 and 3.

Place switch in on position.

CONVECTION OVEN BLOWER

DOES NOT RUN

Replace the switch.

Test blower.

Reinstall the switch cover and

valve panel.

Yes

No

Move a DVM probe to the center terminal of the

switch wires 1 and 2.

Check the voltage specified by the Serial Plate

located behind the oven valve cover panel.

Connect the main power supply.

Is the voltage

as specified?

Reinstall the switch

cover and valve

panel.

Connect the main

power supply.

Check the facility's

power supplies.

Disconnect the main

power supply.

Test oven.

Continues on following page.

Check that one wire is connected

to the (common), 90

°

bottom

terminal of the switch.

Disconnect the main

power supply.

Turn on the power

switch.

Open the oven door.

If the blower runs,

the Door Switch is

wired wrong.

Open the kick panel by raising it

and tilting the top outward.

Move the other wire to the lower

leg (N.O.) on the side of the switch.

Reinstall the switch

cover and valve

panel.

Continuity?

Refer to schematic P/N’s:

1181101 for 120V,

1181102 for 208/240V.

Advertising
This manual is related to the following products: