Sony FCB-EX1020 User Manual

Page 20

Advertising
background image

20

Basic Functions

Sending Alarms

• When motion is detected, the Alarm Replay

command is issued via the serial command (VISCA)
communication line.

• Frame Set

You can set up to four frames by assigning the
starting and terminating points.

Note

Set a terminating point higher vertically and
horizontally than the starting point. If you set the
wrong value, the command yields an error.

8x 01 04 1D 0m 0p 0q 0r 0s FF
m: Select Detection Frame (0: Frame0, 1: Frame1, 2:

Frame2, 3: Frame3)

-- (0, 1, 2, 3)

p: Frame set Start Horizontal Position

-- (00 to 0B)

q: Frame set Start Vertical Position

-- (00 to 07)

r:

Frame set End Horizontal Position

-- (01 to 0C)

s: Frame set End Vertical Position

-- (01 to 08)

• Alarm Reply

When motion is detected in the set frame, the camera
issues this command. This command includes the
information on the number of the detected frame.

y0 07 04 1B 0p FF
p: Frame Number (bit0: Frame0, bit1: Frame1, bit2:

Frame2, bit3: Frame3)

Setting Commands

• MD On/Off

The Display mode is selected by the Function Set
command and frames are set by the Frame Set
command. By sending an MD On command, the
frame is displayed when motion is detected in the set
frame. The Alarm Reply command is set via the
serial command (VISCA) communication line.

8x 01 04 1B 02 FF --- On
8x 01 04 1B 03 FF --- Off

• Function Set

Select the detected frame, and set the Threshold
Level and the Interval Time.

8x 01 04 1C 0m 0n 0p 0q 0r 0s FF
m: Display Mode

on/off (bit0: Frame)

n: Detection Frame set on/off (bit0:Frame0,

bit1:Frame1, bit2:Frame2, bit3:Frame3)

-- (0 to F)

pq: Threshold

-- (00 to FF)

rs: Interval time set

-- (00 to FF)

(When pq and rs are 0, the command is received, but
the setting is disabled.)

Alarm interval

Interval

Motion is
detected
in frame 1.

Interval

Interval

Alarm issue

Alarm issue

Alarm issue

Alarm issue

Motion is
detected
in frame 1.

Motion is
detected
in frame 1.

Motion is
detected
in frame 1.

Motion is
detected
in frame 1.

Motion is
detected
in frame 2.

Motion is
detected
in frame 3.

Motion is
detected
in frame 3.

• When multiple motions are detected or motion is

detected in another frame within the set interval
following the original time the alarm was issued,
another alarm command is not issued.

• When motion is detected after the interval time

elapsed, the alarm is issued again.

Advertising