Diagnosing power problems with the led indicators, Power and cooling problems – SMC Networks SMC TigerStack III SMC6826MPE User Manual

Page 66

Advertising
background image

T

ROUBLESHOOTING

A-2

Diagnosing Power Problems with the LED Indicators

The Power and RPU LED indicators work in combination to indicate
power status as follows.

Table A-2 Power/RPU LED Indicators

Power and Cooling Problems

If the power indicator does not turn on when the power cord is plugged in,
you may have a problem with the power outlet, power cord, or internal
power supply. However, if the unit powers off after running for a while,
check for loose power connections, power losses or surges at the power
outlet, and verify that the fans on the unit are unobstructed and running
prior to shutdown. If you still cannot isolate the problem, the internal
power supply may be defective.

Power LED RPU LED Status

Green

Green

Internal power functioning normally; RPU is

present.

Green

Amber

Internal power functioning normally; RPU plugged

in but faulty.

Green

Off

Internal power functioning normally; RPU not

plugged in.

Amber

Green

Internal power faulty; RPU delivering power.

Off

Off

Both internal power and RPU unplugged or not

functioning.