Specifications, Power management, Ddc (plug & play) – Sharp LL-172G User Manual

Page 30: The analog rgb input connector pin, The dvi-i input connector pin [ll-172g

Advertising
background image

30

Power management

The LL-172A is based on VESA DPMS. The LL-
172G is based on both VESA DPMS and DVI
DMPM. To activate the power management
function, the video card and the computer used
with it must also conform to these standards.

DPMS: Display Power Management Signalling

DMPM: Digital Monitor Power Management [LL-172G]

DDC (Plug & Play)

This monitor supports the VESA DDC (Display
Data Channel) standard.
DDC is a signal standard for carrying out Plug &
Play functions on the monitor or computer. It
transfers information such as degree of resolution
between the monitor and computer. You can use
this function if your computer is DDC compliant
and if it is set so that it can detect the Plug & Play
monitor.
There are many varieties of DDC due to the
differences between systems. This monitor works
with DDC2B.

Specifications

The analog RGB input connector pin

(Mini D-sub connector with 15 pins)

The DVI-I input connector pin [LL-172G]

(DVI-I connector with 29 pins)

1

7

6

5

4

3

2

8

9

15

14

13

12

11

10

16

17

23

22

21

20

19

18

24

C1

C2

C3

C4

C5

No.

Function

1

Red video signal input

2

Green video signal input

3

Blue video signal input

4

GND

5

GND

6

For red video signal GND

7

For green video signal GND

8

For blue video signal GND

9

+5V

10

GND

11

GND

12

DDC data

13

For Hsync signal input

14

For Vsync signal input

15

DDC clock

No.

Function

No.

Function

1

TMDS data 2-

16 Hot plug detection

2

TMDS data 2+

17 TMDS data 0-

3

TMDS data 2/4 shield 18 TMDS data 0+

4

N.C.

19 TMDS data 0/5 shield

5

N.C.

20 N.C.

6

DDC clock

21 N.C.

7

DDC data

22 TMDS clock shield

8

23 TMDS clock +

9

TMDS data 1-

24 TMDS clock -

10 TMDS data 1+

C1 Analog red image signal

11 TMDS data 1/3 shield

C2 Analog green image signal

12 N.C.

C3 Analog blue image signal

13 N.C.

C4

14 +5V

C5 Analog GND

15 GND

Analog vertically
synchronized signal

Analog horizontally
synchronized signal

DMPM mode

Screen

Power

consumption

ON

Display on

35 W

OFF

Display off

1 W

DPMS mode

Screen

Power

H-sync V-sync

consumption

ON

Display on

Yes

Yes

STANDBY

No

Yes

SUSPEND

Display off

Yes

No

OFF

No

No

35 W

1 W