Troubleshooting, Service, Parallel diagrams see – Soundstream Technologies Granite 120.4 User Manual

Page 20: A main power supply fuse, Short-circuit shutdown, Problem cause no sound and are not lit, No power or ground at amp, No remote turn-on signal, Blown fuse near battery, Verify adequate cooling of the amplifier shut-off

Advertising
background image

Your Granite amplifier is protected against both overheating and short circuits by

means of the following circuits:

l

A main power supply fuse

l

A fail-safe

protection circuit activating at 85°C.

. Overcurrent Channel Circuit Breakers

l

Short-circuit shutdown

TROUBLESHOOTING

PROBLEM

CAUSE

No Sound and

are not lit

l

no power or ground at amp

l

no remote turn-on signal

l

blown fuse near battery

l

blown power supply fuse (accessible

through access cover on-bottom of amp)

Repeatedly blown amp fuse or

l

speaker or leads may be shorted

frequent activation of thermal

l

verify adequate cooling of the amplifier

shut-off

l

speaker load may be less than 2 Ohms

SERVICE

Your Soundstream amplifier is protected by a limited warranty. Please read the
warranty card enclosed with this product.

& PARALLEL

DIAGRAMS

See

the diagram below. Note that the manner in which speakers are connected

affects the load presented to the amplifier. Keep your speaker load at 2 ohms or

greater for any Granite amplifier (4 ohms or greater in Bridged Mode).

Two 4 Ohm Speakers

in SERIES 8 Ohms

Two 4 Ohm Speakers

in PARALLEL 2 Ohms

Two Ohm Speakers

in PARALLEL 4 Ohms