680 SERIES

13.5 Panel Flashes FL1 or FL2 (Spas With Circulation

Pump Option)

A flashing “FL1” display means the flow switch is malfunctioning

open, the circulation pump filter cartridge 1 is excessively dirty

or an “air lock” condition has occurred at the circulation pump

intake. A flashing “FL2” display means the flow switch is

malfunctioning closed. In either case, the spa heater will

deactivate and jets pump #1 may also deactivate. To correct
condition perform the following:

1. Verify water level is 1" below lowest pillow. Add water if necessary.
2. Check for clogged or excessively dirty filter cartridges (Section 11.1,

page 30)

3. Purge “air lock” from circulation pump intake by removing filter

cartridge 1 (page 30). Hold your garden hose over the filter cartridge
1 wall fitting (with grate) while using a rag as a seal around hose end.
Ask a helper to turn on water for 30 seconds, then turn off. Reinstall
filter cartridge 1 and check spa (Section 11.1, page 30).

4. If the circulation pump is not running, turn power off at the main

breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.

5. If problem persists, contact your authorized Sundance dealer.

13.6 Panel displays COL
Cool Condition - Temperature has dropped 20°F (11°C) below
the current set temperature. The pump and heater have been
activated to bring the temperature to within 15°F (8°C) of the set
temperature. No corrective action is required.
Note: During cold periods, you may consider increasing the number of
filtration cycles (pages 28-29).

13.7 Panel Displays ICE
Freeze Protection - A potential freeze condition has been

detected. No action is required. The pump and heater will

operate

to circulate and warm water through the plumbing spa is out of
danger. See “Winterizing” Section 11.7 for details (page 33).

13.8 Panel Displays OH
Water temperature is above acceptable limits. Do not enter spa!
Water temperature has reached 112°F (44°C) and the low speed
pump has activated to circulate water through heater.