MAINTENANCE INSTRUCTIONS

11.

After use and before performing maintenance, unplug the device and disconnect the

11.1

inverter from the 12 volt power supply.
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery terminals,

11.2

cords, and the inverter case.
Ensure that all of the inverter components are in place and in good working condition.

11.3

Servicing does not require opening the unit, as there are no user-serviceable parts.

11.4

All other servicing should be performed by qualified service personnel.

11.5

TROUBLESHOOTING

12.

PROBLEM

REASON

SOLUTION

Red LED is on, audible alarm

is on, and/or inverter does not

function.

Poor contact at terminals.

Fuse blown.

Inverter shutdown.

Inverter may not be working

properly.

Check connections at power

supply.

See “IF THE INVERTER

FUSE BLOWS” section.

See “LED INDICATOR AND

SHUTDOWN PROTECTION”

section.

See Warranty and call

Customer Service 1-800-621-

5485 (Hours: 7 am – 5 pm

CST).

BEFORE RETURNING FOR REPAIRS

13.

When an inverter problem arises, make certain that the power supply is operating

13.1

properly (fully charged). Double check all connections for correct polarity and the quality

of the connections from the cables to the connectors and from the connectors to the

inverter. The connectors must be clean.
When an UNKNOWN OPERATING PROBLEM arises, please read the complete manual

13.2

and call the customer service number for information that will usually eliminate the need

for return.

If the above solutions do not eliminate the problem or for information about troubleshooting,

call toll-free from anywhere in the U.S.A.

1-800-621-5485

7:00 am to 5:00 pm Central Time Monday through Friday

SPECIFICATIONS

14.

Model: PI-1000

Maximum Continuous Power

1000 Watts

Surge Capability (Peak Power)

2000 Watts

No Load Current Draw

<0.6A

Wave Form

Modified Sine Wave

Input Voltage Range

10.5V – 15.5V DC

Output Voltage Range

110V – 125V AC

Low Battery Alarm

Audible, 10.3V – 10.6V DC

Low Battery Shutdown

9.7V – 10.3V DC

High Battery Shutdown

15.0V – 16.0V DC

Optimum Efficiency

>85%