Samsung S3C8275X User Manual

Page 184

Advertising
background image

INSTRUCTION SET

S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X

6-50

LD

Load

LD

(Continued)

Examples:

Given: R0 = 01H, R1 = 0AH, register 00H = 01H, register 01H = 20H,
register 02H = 02H, LOOP = 30H, and register 3AH = 0FFH:

LD R0,#10H

R0 = 10H

LD R0,01H

R0 = 20H, register 01H = 20H

LD 01H,R0

Register 01H = 01H, R0 = 01H

LD R1,@R0

R1 = 20H, R0 = 01H

LD @R0,R1

R0 = 01H, R1 = 0AH, register 01H = 0AH

LD 00H,01H

Register 00H = 20H, register 01H = 20H

LD 02H,@00H

Register 02H = 20H, register 00H = 01H

LD 00H,#0AH

Register 00H = 0AH

LD @00H,#10H

Register 00H = 01H, register 01H = 10H

LD @00H,02H

Register 00H = 01H, register 01H = 02, register 02H = 02H

LD R0,#LOOP[R1]

R0 = 0FFH, R1 = 0AH

LD #LOOP[R0],R1

Register 31H = 0AH, R0 = 01H, R1 = 0AH

Advertising