Sio pre-scaler register (siops), Sio block diagram, Figure 14-2. sio prescaler register (siops) – Samsung S3C8275X User Manual

Page 280: Figure 14-3. sio functional block diagram

Advertising
background image

S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X

SERIAL I/O INTERFACE

14-3

SIO PRE-SCALER REGISTER (SIOPS)

The prescaler register for serial I/O interface module, SIOPS, is located at E3H in set 1, bank 0.
The value stored in the SIO pre-scaler register, SIOPS, lets you determine the SIO clock rate (baud rate) as
follows:

Baud rate = Input clock (fxx/4)/(Prescaler value + 1), or SCK input clock.

SIO Pre-scaler Register (SIOPS)

E3H, Set 1, Bank 0, R/W

.7

.6

.5

.4

.3

.2

.1

.0

MSB

LSB

Baud rate = (f

XX

/4)/(SIOPS + 1)

Figure 14-2. SIO Prescaler Register (SIOPS)

SIO BLOCK DIAGRAM

SIO INT

Pending

3-Bit Counter

Clear

SIOCON.0

fxx/2

SIOPS (E3H, set 1, bank 0)

SCK

SIOCON.7

SIOCON.1

(Interrupt Enable)

CLK

SI

SIOCON.3

Data Bus

SO

M

U

X

1/2

8-bit P.S.

8

8-Bit SIO Shift Buffer

(SIODATA, E2H, set 1, bank 0)

CLK

SIOCON.4

(Edge Select)

SIOCON.5

(Mode Select)

SIOCON.2

(Shift Enable)

SIOCON.6
(LSB/MSB First
Mode Select)

Figure 14-3. SIO Functional Block Diagram

Advertising
This manual is related to the following products: