background image

EMBEDDED FLASH MEMORY INTERFACE

S3F8275X

16-10

PROGRAMMING TIP

Program


SB1

LD

FMUSR,#0A5H

; User Program mode enable

LD

FMSECH,#17H

LD

FMSECL,#80H

; Set sector address (1780H

−17FFH)

LD

R2,#17H

; Set a ROM address in the same sector 1780H

−17FFH

LD

R3,#84H

LD

R4,#78H

; Temporary data

CP

UserID_Code,#User_value ; Check user’s ID code (written by user)

; User_value is any value by user

JR

NE,Not_ID_Code

; If not equal, jump to Not_ID_Code

LD

FMCON,#01010001B

; Start program

LDC

@RR2,R4

; Write the data to a address of same sector(1784H)

NOP

; Dummy Instruction, This instruction must be needed

LD

FMUSR,#0

; User Program mode disable

Not_ID_Code: