Figure 17-6. lvr (low voltage reset) timing – Samsung S3C8275X User Manual

Page 304

Advertising
background image

S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X

ELECTRICAL

DATA

17-9

Table 17-6. Battery Level Detector Electrical Characteristics

(T

A

= 25

°

C, V

DD

= 2.0 V to 3.6 V)

Parameter Symbol

Conditions Min

Typ

Max

Unit

Operating voltage of BLD

V

DDBLD

2.0

3.6 V

Voltage of BLD

V

BLD

BLDCON.2-.0 = 000b

2.0

2.2

2.4

BLDCON.2-.0 = 101b

2.15

2.4

2.65

BLDCON.2-.0 = 011b

2.5

2.8

3.1

Current consumption

I

BLD

V

DD

= 3.3 V

70 120

µA

V

DD

= 2.2 V

50 100

Hysteresis voltage of BLD

∆V

BLDCON.2-0 = 000b,
101b, 011b

10 100 mV

BLD circuit response time

T

B

Fw = 32.768 kHz

1 ms

Table 17-7. LVR (Low Voltage Reset) Electrical Characteristics

(T

A

= 25

°

C)

Parameter Symbol

Conditions Min

Typ

Max

Unit

Voltage of LVR

V

LVR

T

A

= 25

°

C

2.0 2.2 2.4 V

V

DD

voltage rising time

t

R

10

µs

V

DD

voltage off time

t

OFF

0.5

s

Hysteresis voltage of LVR

∆V

10 100 mV

Current consumption

I

DDPR

V

DD

= 3.3 V

70 120

µA

NOTES:
1. The current of LVR circuit is consumed when LVR is enabled by "Smart Option"
2. Current consumed when low voltage reset circuit is provided internally.

t

R

t

OFF

0.9 V

DD

0.1 V

DD

V

DD

Figure 17-6. LVR (Low Voltage Reset) Timing

Advertising