Operating mode characteristics, Table 19-3. operating mode selection criteria – Samsung S3C8275X User Manual

Page 315

Advertising
background image

S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X

S3F8275X/F8278X/F8274X FLASH MCU

19-5

OPERATING MODE CHARACTERISTICS

When 12.5 V is supplied to the V

PP

(TEST) pin of the S3F8275X/F8278X/F8274X, the Flash ROM programming

mode is entered.
The operating mode (read, write, or read protection) is selected according to the input signals to the pins listed in
Table 19-3 below.

Table 19-3. Operating Mode Selection Criteria

V

DD

V

PP

(TEST)

REG/MEM Address

(A15-A0)

R/W Mode

3.3 V

3.3 V

0

0000H

1

Flash ROM read

12.5 V

0

0000H

0

Flash ROM program

12.5 V

1

0E3FH

0

Flash ROM read protection

NOTES:
1. The

V

PP

(Test) pin must be connected to V

DD

(S3F8275X only).

2. "0" means Low level; "1" means High level.