Siemens Chem-Ad Series User Manual

Page 3

Advertising
background image

SELECTION CODE (EXAMPLE)

CM

1

A4

E60

K

F

C

99

31

Valve Balls
C
= Ceramic
O-Ring
F
= Viton; E = EPDM;
K = FFPM/Isolast
Pump Head
K
= PVDF
Control Mode
E60
= Auto Control with Digital
Display
E30
= Auto Control, Basic
E11 = Manual
Capacity
50HZ 60HZ
A1
= 0.20 LPH 0.06 USGPH
A2 = 0.50 LPH 0.16 USGPH
A3 = 0.09 LPH 0.29 USGPH
A4 = 0.90 LPH 0.44 USGPH
Voltage & Cycles
1
= 115 V. 60 Hz;
3 = 230 V. 50 Hz

Options / Series A

E11

E30

E60

E60 Plus

ON-OFF Button

X

X

X

X

Manual Stroke Length Control

X

X

X

X

Stroke Frequency Control

X

X

X

Level Switch Input (low level and empty)

X

X

X

X

Power Cord and Plug

X

X

X

X

External Analog Input (0-20 or 4-20 mA)

X

X

X

External Analog Input (0/4-20 mA) or (20-4/0 mA )

X

X

Input Signal Scaling

X

X

External Pulse Input

X

X

X

Remote On / Off

X

X

X

Batch Mode & Pulse Storage

X

X

Alarm Output & Stroke Pulse Output

X

X

X

Membrane Touch Pad

X

X

Flow Monitoring (OGM Required)

X

X

Integral Back-Lit Digital Display

X

X

Password Protection

X

X

Capacity Display

X

X

Multiple Language Display (English, German, French)

X

X

Flow Totalizing

X

Set Point Control

X

Selection Guide

To allow easy selection, the Chem-

Ad series is engineered to the

modular design principle. The

selection criteria shown below

provides a perfect guide to define

the right pump for the respective

duty.

Note - E60 Plus models require ICP & OGM combination.

Advertising